有机化合物及其作为基于分子MR的温度传感器的用途
Christian Bruns1, Rainer Ringleb1, Isabell Prediger1
1Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany.
概括
化有机化合物可以使用19F NMR作为内部温度计. 它们的信号转移揭示了溶液中的局部温度,这对于化学反应堆和医学诊断中的应用至关重要.
科学领域:
- 分析化学 分析化学
- 物理化学 物理化学
- 有机化学 有机化学
背景情况:
- 由于其独特的特性,人们对化物质的兴趣越来越大.
- 核磁共振 (NMR) 光谱对于分析结构和分子环境至关重要.
- 精确的温度测量在各种科学和医疗应用中至关重要,但在某些环境中具有挑战性.
研究的目的:
- 为了研究化有机化合物中19F NMR信号的温度灵敏度.
- 评估这些化合物作为内部温度计的潜力,以确定溶液中的局部温度.
- 探索多化分子作为自校准温度计的使用.
主要方法:
- 选择了13种化有机化合物进行分析.
- 检查了19F NMR信号的温度灵敏度.
- 研究的多化分子具有明显的19FNMR信号.
- 测量信号的变化是以百万分之一克尔文 (ppm/K) 的单位.
主要成果:
- 检测到一个高达0.03 ppm/K的19FNMR信号转移.
- 证明多化分子可以作为内部的,纠错的温度计.
- 发现的位置和化学环境显著影响温度灵敏度.
结论:
- 化有机化合物适用于基于19F NMR的温度计.
- 这些化合物可以作为内部温度计,而不需要参考物质.
- 这些发现支持在化学反应器和医学诊断中应用19FNMR温度计.
相关概念视频
Fluorescence and Phosphorescence: Instrumentation
641
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
641
Atomic Fluorescence Spectroscopy
419
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
419
Photoluminescence: Applications
429
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
429
Halogens
18.5K
Group 17 elements, known as halogens, are nonmetals. At room temperature, fluorine and chlorine are gases, bromine is a liquid, and iodine a solid. Astatine is a highly unstable radioactive element, so currently, most of its properties are unknown due to its short half-life. Tennessine is a synthetic element also predicted to be in this group.
18.5K
Flame Photometry: Lab
274
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
274
Equipments Used to Measure Body Temperature
1.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.1K