高血压老年患者的虚拟现实游戏:一项初步研究以确定负载强度和血压
Susan Vorwerg-Gall1, Oskar Stamm2, Michele Haink2
1Department of Geriatrics and Medical Gerontology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Reinickendorfer Straße 61, 13347, Berlin, Germany. susan.vorwerg@charite.de.
BMC geriatrics
|August 29, 2023
概括
虚拟现实 (VR) 游戏可以帮助高血压的老年人降低血压 (BP). 中等强度的VR强度耐力训练在运动后实现了显著的BP降低.
科学领域:
- 运动生理学 运动生理学
- 心血管健康 心血管健康
- 虚拟现实技术 虚拟现实技术
背景情况:
- 改变生活方式和身体活动对于控制高血压至关重要.
- 虚拟现实 (VR) 游戏在降低血压方面的有效性仍未得到充分研究.
- 这项研究探讨了VR运动游戏负载强度和对BP的短期影响.
研究的目的:
- 为了确定在VR游戏中可实现的负载强度.
- 评估VR游戏对血压的直接影响.
- 评估VR游戏对老年人高血压管理的潜力.
主要方法:
- 一项初步研究涉及22名65岁以上的高血压患者.
- 参与者进行了两次25分钟的VR训练:VR强度耐力训练 (VR-SET) 和VR耐力训练 (VR-ET).
- 测量包括心率,血压 (BP) 会议前后,感知劳动力 (RPE) 评级和NASA任务负载指数.
主要成果:
- 在VR-SET和VR-ET之间观察到负载强度和最大心率的显著差异.
- VR-SET使更多的参与者能够达到中等强度 (40%的心率储备).
- 在两个VR课程中,缩血压在运动后5分钟和10分钟显著下降.
结论:
- 通过VR-SET,可以达到适度的运动强度.
- 虚拟现实运动游戏对血压产生了积极的短期影响,表明运动后的低血压.
- 初步发现表明VR游戏可以有效地降低高血压的老年人的血压.
相关概念视频
Pre-Procedural Guidelines for Assessing Blood Pressure
595
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
595
Equipments Used To Measure Blood Pressure
1.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Special considerations while measuring blood pressure
755
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
755
Assessing Blood pressure in the Leg
2.9K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
2.9K
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K
Exercise Stress Test
271
Introduction
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
271


