相关实验视频
Updated: Jul 17, 2025

10:53
Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
5.5K
一个自动化声波断层扫描系统用于检查历史性体墙壁
Javier Ortega1, Marnix F L Meersman2, Sofía Aparicio1
1Institute of Physical and Information Technologies (ITEFI), Agencia Estatal Consejo Superior de Investigaciones Cientificas, Madrid, Community of Madrid, 28006, Spain.
Open research Europe
|August 30, 2023
概括
一个新的自动化声波断层扫描系统快速检查历史性的墙,提供详细的洞察力,他们的内部结构和损坏. 这种非破坏性技术为遗产保护专业人士提供了实际的解决方案.
科学领域:
- 遗产科学科学 遗产科学
- 结构健康监测 结构健康监测
- 非破坏性测试 不破坏性测试
背景情况:
- 建筑遗产的保护需要了解几何,结构和材料的特性.
- 对于测量有价值的历史建筑而言,非破坏性技术至关重要.
- 目前的手工方法耗时,限制了现场应用.
研究的目的:
- 开发和验证一个自动化声波断层扫描系统,用于检查历史性墙.
- 为了克服手动,耗时的调查技术的局限性.
- 为遗产专业人士提供实用工具.
主要方法:
- 设计和制造了一种自动化的声波断层扫描系统,配有可移动的击中装置和扫描激光振动计.
- 该系统产生声波并记录它们通过墙的传播.
- 在六个实验室建造的具有已知的内部几何形状的石头墙上测试了该系统.
主要成果:
- 自动化系统在几个小时内有效地收集了数千个数据点.
- 开发了用于自动化数据处理的新软件.
- 扫描图像与地面真相数据进行比较以验证.
结论:
- 自动声波断层扫描显著加快了墙壁检查数据收集和处理的速度.
- 开发的系统提供了一种实用和定量方法来评估遗产结构的内部.
- 公开发布的数据,软件和模型支持进一步的遗产保护研究和应用.
相关概念视频
Masonry Cavity Walls
1.0K
Cavity walls feature a hollow space between the outer and inner wythes, connected only by corrosion-resistant metal ties. When water seeps through the outer wythe, it descends within this cavity, intercepted by flashing and eventually exiting through weep holes. To enhance moisture resistance, the inner wythe's cavity side often receives damp-proofing, doubling as an air barrier. The cavity can also house insulation to mitigate heat transfer.
Maintaining a clean cavity during construction...
Maintaining a clean cavity during construction...
1.0K
Composite Masonry Walls
1.2K
Composite masonry walls combine multiple wythes of the same or different masonry materials to create a unified structure. These walls feature wythes that are bonded together either through mortar-filled collar joints, grouted spaces, or more commonly, with rigid metal ties and reinforcements, with the use of masonry header units being rare. Metal ties are preferred because they effectively minimize water penetration, as these walls primarily absorb moisture and then release it into the...
1.2K
Masonry Curtain Walls
1.1K
Masonry curtain walls employ brick or stone veneers supported by the building's structure to form an external cladding system that is both aesthetically appealing and functional. These walls are erected through two principal techniques, first by traditional layering of masonry units and second by using prefabricated panels. Traditional construction relies on steel shelf angles attached to the spandrel beam for support, with high-bond mortars ensuring secure attachment of masonry veneer...
1.1K
Expansion and Contraction in Masonry Walls
976
Masonry walls are subject to slight expansion and contraction due to variations in temperature and moisture. Thermal movement in masonry is relatively straightforward to measure and plan for. On the other hand, moisture movement poses more of a challenge. New clay masonry units typically absorb water and expand over time under normal environmental conditions. Conversely, new concrete masonry units tend to shrink as they lose the excess moisture acquired during their production process.
To...
To...
976
Thermal Insulation in Masonry Walls
147
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
147
Posttensioned Masonry Walls
168
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
168