对于共聚焦激光内分显微镜图像消噪的上下文感知动态过网络
Jingjun Zhou1, Xiangjiang Dong2, Qian Liu1,3
1School of Biomedical Engineering, Hainan University, 570228 Haikou, People's Republic of China.
Physics in medicine and biology
|August 30, 2023
概括
聚焦激光内分显微镜 (CLE) 图像往往很,阻碍了胃肠道疾病的诊断. 我们开发了一种新的自我监督的除方法,CLENet,以提高图像质量并减少误诊率.
科学领域:
- 医疗成像医学成像
- 计算机视觉 计算机视觉
- 胃肠病学 胃肠病学
背景情况:
- 聚焦激光内微镜 (CLE) 是诊断胃肠道疾病的关键技术.
- 图像噪声源于光纤捆的物理结构,显著降低了CLE图像质量.
- 现有的无声化技术在CLE图像中难以实现现实的噪声模式.
研究的目的:
- 在CLE图像中开发先进的无声化方法,以实现现实的噪声.
- 提高使用CLE检测胃肠道疾病的诊断准确度.
- 创建一个不需要清洁参考图像的自主监督的无雾化模型.
主要方法:
- 构建了一个针对CLE数据的现实噪声模型.
- 开发了情境感知内核估计 (CLENet) 来处理不均的噪音.
- 在U型网络 (U-CLENet) 中集成了一个多尺度的动态融合模块.
主要成果:
- 在CLE图像数据集上实现了与现有方法相比或优于现有方法的性能.
- 对于拟议的无线化网络来说,已经证明了低计算复杂度.
- 成功地从CLE图像中删除了乘法和加法白噪声.
结论:
- 拟议的U-CLENet有效地提高了CLE图像的视觉质量.
- 提高图像清晰度有助于诊断胃肠道瘤的各个阶段.
- 该方法支持计算机辅助诊断,可能减少临床误诊率.
相关概念视频
Confocal Fluorescence Microscopy
13.4K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
13.4K
Three-Dimensional Microscopy in Microbiology
65
Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
65
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Imaging Biological Samples with Optical Microscopy
4.8K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
4.8K
Phase Contrast and Differential Interference Contrast Microscopy
8.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.2K