扩散到铜电流采集器中的扩散对无阳极金属电池中电沉积的影响
Yu-Kai Huang1, Heyin Chen1, Leif Nyholm1
1Department of Chemistry - Ångström Laboratory, Uppsala University, Box 538, Uppsala, SE-751 21, Sweden.
Small (Weinheim an der Bergstrasse, Germany)
|September 4, 2023
概括
改善铜上的核化是无阳极金属电池的关键. 化学预化和铜表面,使沉积更均,电池性能更好.
科学领域:
- 电化学 电化学 电化学
- 材料科学 材料科学 材料科学
- 储能 储能 储能 储能 储能 储能
背景情况:
- 无阳极的金属电池提供高能量密度,但在控制铜电流集电器上的核化方面面临挑战.
- 了解核化及其与铜基板的相互作用对于提高电池性能至关重要.
研究的目的:
- 为了研究扩散到铜基板中的扩散对核化的影响.
- 确定改善铜表面均核化的方法.
主要方法:
- 对铜上的核的电化学分析.
- 表面表征技术用于研究-铜相互作用.
- 在沉积之前应用化学预化.
主要成果:
- 扩散到铜粒边界显著阻碍了均的核和导致不均的电位.
- 铜表面的化学预化有效地使其和.
- 前化减少了扩散的影响,促进了统一的核化.
结论:
- 化学预化是一种可行的策略,可以在铜基板上增强均核化.
- 优化的预化与潜在静态核化脉冲相结合,改善了先进电池应用的沉积.
相关概念视频
Electrodeposition
664
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
664
Voltaic/Galvanic Cells
57.5K
Spontaneous Chemical Reactions
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
57.5K
Voltammetry: Factors Affecting Measurements
180
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
180
Controlled-Current Coulometry: Overview
239
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
239
Electrogravimetric Analysis: Overview
271
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
271
Controlled-Potential Coulometry: Electrolytic Methods
208
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
208