高稳定的兰化物 (III) 金属有机框架作为维生素B的比度光传感器
Xiao-Qing Wang1,2, Jiandong Yang1, Man Zhang1
1Department of Chemistry, College of Science, North University of China, Taiyuan 030051, China. xqwang@nuc.edu.cn.
Dalton transactions (Cambridge, England : 2003)
|September 7, 2023
概括
新的化金属有机框架 (Ln-MOFs) 显示双光,并作为维生素B6的选择性传感器. 这些稳定的MOF在水溶液和实物样本中提供了灵敏的检测.
科学领域:
- 材料科学:新型基于化物的金属有机框架 (Ln-MOFs) 的合成和表征.
- 协调化学:研究六核兰坦化集群与刚性四碳酸联体.
- 分析化学:开发用于维生素B6检测的发光传感器.
背景情况:
- 基于兰化物的金属有机框架 (Ln-MOF) 因其独特的发光特性而受到探索.
- 开发对像维生素B6这样的生物相关分子有选择性和敏感的传感器仍然是一个挑战.
- 对于传感应用来说,Ln-MOF的稳定性和可调节的发光度至关重要.
研究的目的:
- 综合和描述具有特定集群结构和拓的新型Ln-MOF.
- 研究这些Ln-MOF的发光特性,包括双光和色调.
- 评估这些Ln-MOF作为维生素B6的比度光传感器的潜力.
主要方法:
- 使用H4EBTC联体物进行三种基于兰化物(III) 的金属有机框架 (Ln = Eu,Tb,Ce) 的溶热合成.
- 具有ftw拓的12连接的六核[Ln6(μ3-OH) 8(OOC-) 12(H2O) 6集群的结构特征.
- 光发光光谱学用于研究光辐射,天线效应和维生素B6的传感能力.
主要成果:
- 成功合成稳定的Ln-MOFs,从Ln3+离子和H4EBTC连接体中表现出双光.
- 在合的双金属Eu/Tb-MOF中可调节的发光,显示颜色从红色变为绿色.
- 高选择性和可重复使用性,用于低检测极限 (0.11-1.03μM) 的维生素B6检测,使用比度光传感.
结论:
- 合成的Ln-MOF具有坚固的结构和可调节的发光特性.
- 这些Ln-MOF在各种介质中展示了作为维生素B6的比度光传感器的卓越性能.
- 基于视觉薄膜的传感器 (Ln-MOF@SA) 已被开发用于实用的维生素B6检测,具有很高的可重复使用性.
更多相关视频
13:21Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
15.0K
08:31Luminescence Resonance Energy Transfer to Study Conformational Changes in Membrane Proteins Expressed in Mammalian Cells
Published on: September 16, 2014
12.1K
相关概念视频
Photoluminescence: Applications
428
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
428
Colors and Magnetism
11.8K
Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
11.8K
Complexometric Titration: Overview
7.3K
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free...
7.3K
Complexometric Titration: Ligands
988
Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...
988
