用数据驱动方法重建的磁共振图像中的分辨率和噪声的评估
Jonas Kleineisel1, Katja Lauer2, Alfio Borzì3
1Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany; Institut Desbrest d'Épidémiologie et de Santé Publique, Univ Montpellier, INSERM, Montpellier, France.
Zeitschrift fur medizinische Physik
|September 8, 2023
概括
深度学习MRI重建方法比传统技术提供了更好的图像质量. 与压缩传感和GRAPPA相比,像VN和U-Net这样的数据驱动方法显示出较少的模糊和减少噪声增强.
科学领域:
- 医疗成像医学成像
- 机器学习 机器学习
- 图像重建 图像的重建
背景情况:
- 加速MRI重建越来越多地使用深度学习.
- 对分辨率和信号噪声比的详细评估往往缺乏.
- 本研究通过评估常见的重建方法来解决这一差距.
研究的目的:
- 为了空间地映射图像分辨率和噪声增强 (g-因子).
- 评估典型的模型和数据驱动的MR重建方法.
- 为分析新的重建方法提供一个框架.
主要方法:
- 常规大脑MRI数据的回顾性下面样本 (R=4) .
- 使用变量网络 (VN),U-Net,GRAPPA和电视受约束的压缩传感重建.
- 通过点传播函数宽度进行本地分辨率估计;使用多个复制品进行g因子映射.
主要成果:
- 格拉帕的分辨率很好,但g因子 (1.43-1.84) 较高.
- 压缩传感导致局部分辨率较低,特别是在同质区域.
- VN和U-Net显示了可比的分辨率与中度模糊;U-Net略好一些.
- 分辨率和g因子根据CS,VN和U-Net的解剖学和低采样方向而有所不同.
结论:
- 确定了客观的质量参数 (分辨率,g因子).
- 数据驱动的方法 (VN,U-Net) 比压缩传感显示的模糊性要小.
- 噪声增强在CS,VN和U-Net的轮上升,但与GRAPPA相比降低.
- 该框架允许对先进的重建技术进行详细分析.
相关概念视频
Magnetic Resonance Imaging
5.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.2K
NMR Spectrometers: Resolution and Error Correction
720
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
720
Atomic Nuclei: Magnetic Resonance
681
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
681
Imaging Studies IV: Magnetic Resonance Imaging
25
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
25
Double Resonance Techniques: Overview
241
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
241