交叉组件可转换的变压器管道服从动态摇摆,用于具有不平衡数据的旋转机械
Binbin Xu1, Boquan Ma1, Zheng Yang2
1Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen 518118, China.
Sensors (Basel, Switzerland)
|September 9, 2023
概括
这项研究引入了一种新的可转移管道,用于诊断旋转机械故障,即使数据不平衡. 该方法增强了特征提取,并提高了跨多个组件的诊断准确性.
科学领域:
- 机械工程 机械工程
- 信号处理 信号处理
- 人工智能的人工智能
背景情况:
- 旋转机械的数据驱动故障诊断受到不足的故障数据和复杂的操作条件的阻碍.
- 现有的方法与不平衡的数据集以及为各种组件提取强大的特征而斗争.
研究的目的:
- 为面对不平衡数据的多个旋转机械部件开发可转移的故障诊断管道.
- 在具有挑战性的操作条件下增强特征提取和诊断精度.
主要方法:
- 改进了同步压缩波形变换 (SWT) 以提高时间频特征表示.
- 提出了一种具有动态摇摆 (HWT-SS) 的新型层次窗口变压器,用于特征提取和样本平衡.
- 实现组件之间的转移诊断,以利用来自多个来源的数据.
主要成果:
- 与四个数据集的基准模型相比,HWT-SS模型展示了优越的特征提取能力.
- 拟议的管道显示对不平衡数据的敏感性降低.
- 转移诊断显著改善了诊断性能,特别是对于高度不平衡的数据集.
结论:
- 开发的可转移管道有效地解决了不平衡数据的旋转机械故障诊断挑战.
- 增强SWT和HWT-SS的组合为复杂的工业应用提供了强大的解决方案.
- 转移诊断是提高故障诊断系统可靠性的有希望的策略.
相关概念视频
Energy Losses in Transformers
901
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
901
Per-Unit Sequence Models
93
An ideal Y-Y transformer, grounded through neutral impedances, displays per-unit sequence networks akin to those of a single-phase ideal transformer when subjected to balanced positive- or negative-sequence currents. These currents do not produce neutral currents, and their associated voltage drops.
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
93
Transformers in Distribution System
123
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
123
Instrument Transformers
106
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
106
Types Of Transformers
1.0K
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
1.0K
Three-Winding Transformers
256
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
256