为ITER中性粒子诊断系统开发和测试二次离子加速器
V I Afanasyev1, F V Chernyshev1, S S Kozlovsky2
1Ioffe Institute, 26 Politekhnicheskaya Street, Saint-Petersburg 194021, Russia.
The Review of scientific instruments
|September 11, 2023
概括
一个新的二次离子加速器增强了ITER的性能.
科学领域:
- 核聚变能源的研究.
- 血诊断仪器的使用
- 粒子加速器技术的技术
背景情况:
- 为了进行血分析,ITER需要先进的诊断技术.
- 中性粒子分析仪 (NPA) 测量逃逸的等离子体粒子.
- 改善信号/背景比对于低能粒子检测至关重要.
研究的目的:
- 为ITER的NPA诊断综合体开发和测试一个二次离子加速器.
- 提高NPA测量的信号/背景比,特别是在10-50 keV.
- 在ITER运行条件下确保加速器的可靠性.
主要方法:
- 设计了一个加速器,将中性原子转化为离子,并将它们加速到+100kV.
- 整合了一个用于现场更换剥离片的单元.
- 使用一个密封的钢外与气绝缘 (6巴).
主要成果:
- 二级离子加速器成功地转换和加速粒子.
- 设计方便有效地更换剥离片.
- 测试证实在模拟ITER条件下 (马辐射,地震负荷) 的高可靠性.
结论:
- 开发的二次离子加速器对于ITER的诊断综合体是可靠的.
- 它显著提高了中性粒子分析仪的性能.
- 这项技术对于融合反应堆中精确的等离子体诊断至关重要.
相关概念视频
Mass Analyzers: Common Types
642
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
642
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
253
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
253
Tandem Mass Spectrometry
1.1K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.1K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
784
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
784