研究LiMgPO4:Dy光的热发光和光学刺激的发光,通过不同的方法合成
Zilong Yin1, Henglei Chen1, Guangwen Feng1
1School of Physics and Technology, Xinjiang University, 830017, Urumqi, China.
概括
与固态方法相比,sol-gel方法产生了优异的LiMgPO4:Dy,表现出增强的热发光和光学刺激的发光特性,可用于辐射剂量计.
科学领域:
- 材料科学 材料科学 材料科学
- 发光的光度是非常的低.
- 固态化学 固态化学
背景情况:
- 酸与 (LiMgPO4:Dy) 的合物是发光应用的一个有前途的材料.
- 了解合成方法对的特性的影响对于优化性能至关重要.
研究的目的:
- 研究高温固态和溶凝合成方法对LiMgPO4:Dy的影响.
- 为了比较用不同的方法制备的光体的晶体结构,形态学,热发光 (TL) 和光学刺激发光 (OSL) 特性.
主要方法:
- 使用高温固态和sol-gel方法合成LiMgPO4:Dy.
- 使用X射线衍射 (XRD) 和扫描电子显微镜 (SEM) 进行表征.
- 评估TL和连续波OSL (CW-OSL) 的特性.
主要成果:
- 这两种方法都产生了LiMgPO4晶相.
- 与固态方法相比,Sol-gel方法导致了改善的形态和显著更高的TL和OSL灵敏度.
- 最高的TL发光温度为363K (固态) 和380K (sol-gel).
- 合成方法没有影响OSL衰变特征.
结论:
- sol-gel方法为合成具有增强发光特性的LiMgPO4:Dy光体提供了优势.
- 通过sol-gel合成的LiMgPO4:Dy是辐射剂量计应用的潜在候选者.
相关概念视频
Photoluminescence: Applications
428
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
428
Photoluminescence: Fluorescence and Phosphorescence
2.1K
Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
A pair of electrons in a...
2.1K
Fluorescence and Phosphorescence: Instrumentation
640
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
640
Variables Affecting Phosphorescence and Fluorescence
526
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
526
Flame Photometry: Overview
655
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
655
Flame Photometry: Lab
272
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
272