概括
一个新的双通道快照成像光谱仪 (DSIS) 在紧的设计中实现了广谱和高分辨率. 这项技术克服了当前动态目标分析系统的局限性.
科学领域:
- 光学和光子学 在光学和光子学.
- 影像科学 影像科学
- 频谱学是一种光谱学.
背景情况:
- 动态目标分析需要即时捕获空间和光谱信息.
- 目前的快照光谱成像系统在广泛的光谱范围和高分辨率方面扎.
- 现有技术面临的挑战是同时实现广谱覆盖和高空间分辨率.
研究的目的:
- 引入一种新的双通道快照成像光谱仪 (DSIS),能够提供广谱和高分辨率.
- 克服现有的快照光谱成像系统的局限性.
- 开发一个紧的成像光谱仪,用于动态目标分析.
主要方法:
- 开发了一种双通道成像方法,将光谱范围分成两部分,减少光谱重叠.
- 优化了垂直于分散方向的视野 (FOV),以平衡FOV和纹.
- 设计了一个紧的结构,整合了广泛的光谱范围和高分辨率功能.
主要成果:
- DSIS实现了53x11的空间元素,最多有250个频谱通道.
- 从400到795 nm的广泛光谱中获取的数据.
- 在一个紧的形式因素中,已证明具有广泛的光谱范围和高分辨率的能力.
结论:
- 新的DSIS技术成功地将广谱范围和高分辨率集成到一个紧的设计中.
- 双通道方法有效地减轻了光谱重叠,提高了系统性能.
- DSIS为动态目标的即时空间和光谱分析提供了一个有前途的解决方案.
相关概念视频
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
253
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
253
Atomic Emission Spectroscopy: Instrumentation
520
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
520
UV–Vis Spectrometers
1.4K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.4K
Atomic Absorption Spectroscopy: Instrumentation
781
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
781
Tandem Mass Spectrometry
1.1K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.1K
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K