评估过面片呼吸器的弹性体头带的性能
Okrasa Małgorzata1, Cheberyachko Serhii2, Radchuk Dmytro2
1Department of Personal Protective Equipment, Central Institute of Labour Protection - National Research Institute (CIOP-PIB), Poland.
International journal of occupational safety and ergonomics : JOSE
|September 15, 2023
概括
过面部呼吸器 (FFR) 的重复使用会降低弹性头带的性能,降低保护. 由于显著的弹性损失和带延长,需要在八次使用后进行带调整.
科学领域:
- 职业健康和安全问题 职业健康和安全问题
- 材料科学 材料科学 材料科学
- 生物医学工程 生物医学工程
背景情况:
- 过面部呼吸器 (FFR) 对于呼吸保护至关重要.
- 频繁的穿戴和脱落可以通过变形弹性头带来损害FFR的有效性.
- 头带弹性的降解导致呼吸器适合性和保护因子降低.
研究的目的:
- 为了研究FFR头带在重复使用时的弹性损失.
- 量化着装和脱落周期对皮带性能的影响.
- 为设计更耐用,更有效的FFR提供信息.
主要方法:
- 测试了五条弹性带作为FFR头带.
- 经过重复的穿戴和脱落周期后,使用DU-100动力表测量了抗拉强度.
- 分析了皮带延长作为力和循环数的函数.
主要成果:
- 在八次连续使用后观察到保护因子的显著下降.
- 头带弹性损失和残余延长在八个周期后仍然保持一致.
- 确定了皮带延长,施加的力和穿戴/脱落周期的数量之间的关系.
结论:
- 弹性头带变形在重复使用时显著影响FFR的有效性.
- 了解皮带延长对于设计具有持续保护的改进FFR至关重要.
- 建议探索替代材料,以提高FFR性能和用户舒适度.
相关概念视频
Personal Protective Equipment
1.6K
Personal protective equipment (PPE) is unique clothing or equipment worn by an employee to minimize or prevent exposure to infectious agents. PPE creates a barrier between the employee and the infectious materials. PPE must be readily available in the patient care area. PPE includes gloves, gowns and aprons, masks and respirators, goggles, face shields, shoes, and headcovers:
1.6K
PPE Use in Healthcare Settings I: Donning
1.0K
Donning PPE must be completed before contact with the patient. This process protects from infectious agents. The sequence and action included in each donning are critical, and the steps must be systematic to avoid exposure to pathogens. The institutional policy also needs to be followed while donning PPE. The pre-donning preparations are gathering equipment, inspecting the PPE equipment for tears, holes, or damage, removing jewelry, removing any garments below the elbows, and tying the hair...
1.0K
Assessment of Airway, Skin Color, and Use of Accessory Muscles
1.0K
A thorough assessment of respiratory health is paramount in clinical settings to identify and manage respiratory distress and ensure adequate oxygenation. This article elaborates on the critical aspects of respiratory evaluation, including airway assessment, skin color examination, and the observation of accessory muscle use, which are integral to effectively diagnosing and managing patients with respiratory conditions.
Introduction
The initial evaluation of a patient's respiratory system...
Introduction
The initial evaluation of a patient's respiratory system...
1.0K
PPE Use in Healthcare Settings II: Doffing
947
The sequence of removing or doffing PPE starts with the gloves, as they are the most contaminated. Next is removal of the face shield or goggles, as they would interfere with removing other PPE. Then remove the gown, followed by the mask or respirator. Perform hand hygiene between steps if hands become contaminated and immediately after removing all PPE. Generally, the outside front and sleeves of the isolation gown, the goggles or the mask, the respirator, and the face shield are contaminated.
947