合成分子光谱建模用于确定低压等离子体的旋转,振动和激发温度
Jonggu Han1, Woojin Park1, Jongsik Kim2
1Department of Applied Plasma and Quantum Beam Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Republic of Korea.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
|September 16, 2023
概括
这项研究使用先进的数值模拟来分析等离子体的热特性. 结果显示,旋转,振动和激发温度之间存在明显的关系,这对于工业应用至关重要.
科学领域:
- 等离子体物理学的物理学
- 频谱学是一种光谱学.
- 化学工程是化学工程的重要组成部分.
背景情况:
- 等离子体的高反应性在工业中很有价值.
- 控制等离子体特性需要了解热特性.
- 理想的反应物取决于精确的血控制.
研究的目的:
- 为了确定感应合等离子体的热特性.
- 为了研究旋转,振动和激发温度.
- 为了将这些温度与等离子体输入功率相关联.
主要方法:
- 使用合成光谱集群的高级数值模拟.
- 对三个分子带系统的分析:N2 B-A,N2 C-B和N2+ B-X.
- 在等离子体中测量温度 (5 mTorr,50 W - 900 W).
主要成果:
- 旋转和振动温度随着输入功率的增加而增加,显示了约250W的拐点.
- 激发温度下降到250W以下,在250W以上升高.
- 能量状态不处于热平衡;振动和激发温度相互相关.
结论:
- 该研究提供了控制等离子体的关键热数据.
- 观察到非平衡条件,突出显示了复杂的血动态.
- 讨论了解离,电离和激发温度之间的相关性.
相关概念视频
Atomic Spectroscopy: Effects of Temperature
363
Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
363
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
1.1K
The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
1.1K
Atomic Emission Spectroscopy: Lab
195
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
195
UV–Vis Spectroscopy: Molecular Electronic Transitions
1.6K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.6K
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
1.1K
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
1.1K
Emission Spectra
54.1K
When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
54.1K