优化织物阶段吸附提取协议,从果汁袋中分离六种双,通过高性能液体染色学与二极管阵列探测器相结合进行分析
Paweł Kubica1, Natasa P Kalogiouri2, Abuzar Kabir3
1Department of Analytical Chemistry, Faculty of Chemistry, Gdansk University of Technology, 11/12 Narutowicza Str., Gdańsk, 80-233, Poland; Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124, Thessaloniki, Greece.
Journal of chromatography. A
|September 16, 2023
概括
使用织物阶段吸附提取 (FPSE) 和HPLC-DAD的新方法同时检测到六种双在果汁袋中. FPSE方法可重复使用,为双醇分析提供高精度和灵敏度.
科学领域:
- 分析化学 分析化学
- 环境科学 环境科学
背景情况:
- 双是食品包装中发现的内分泌干扰化学物质.
- 果汁袋是双暴露的常见来源,需要可靠的检测方法.
研究的目的:
- 开发和验证一种同时测定六种双 (BPA,BPB,BPC,BPE,BPF,BPS) 在果汁袋中的方法.
- 优化织物阶段吸附提取 (FPSE) 程序,以实现高效的双提取.
主要方法:
- 织物阶段吸附提取 (FPSE) 与高性能液体染色学-二极管阵列检测 (HPLC-DAD) 相结合.
- 优化关键的FPSE参数:膜类型/大小,吸附/提取时间,脱吸溶剂,和添加盐.
- 验证FPSE-HPLC-DAD方法的线性,灵敏度,准确度和精度.
主要成果:
- FPSE膜的可重复使用性达到了14倍.
- 已达到低检测极限 (LODs < 6.9 ng/mL) 和量化极限 (LOQs < 21 ng/mL).
- 证实了高准确度 (康复率>86%) 和精度 (CV<9.5%).
结论:
- 开发的FPSE-HPLC-DAD方法对于在果汁袋中同时测定双是有效的.
- 该方法提供了一种灵敏,准确和可重复的方法来分析食品包装中的双醇.
- FPSE膜的可重复使用性提高了该方法的成本效益和可持续性.
相关概念视频
Optimizing Chromatographic Separations
433
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
433
Analyte Adsorption and Distribution
692
In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and...
692
High-Performance Liquid Chromatography: Elution Process
530
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
530