质子对光子综合节点乳房照射
1Department of Radiation Oncology, Robert Wood Johnson University Hospital, New Brunswick New Jersey.
概括
与传统的光子技术相比,质子疗法在全面的节点乳房照射期间显著降低了肺部和心脏的辐射剂量. 这种方法提供了一个更安全的替代方案,特别是当标准剂量约束难以满足光子时.
科学领域:
- 辐射瘤学 辐射瘤学
- 医学物理 医学物理
背景情况:
- 传统的3DCRT规划全面的节点乳房照射使用三或四场光子技术.
- 这种技术可以导致涉及到双侧肺和心脏剂量,这取决于患者的解剖学.
- 既定的剂量限制旨在将肺V20限制在<35%和心脏平均剂量限制在<3Gy.
相关概念视频
Radiation: Applications
1.2K
The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
The average...
1.2K
Biological Effects of Radiation
15.5K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
15.5K
Absorption of Radiation
761
The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
761
Positron Emission Tomography
4.3K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
4.3K
Radiation Pressure: Problem Solving
394
The radiation pressure applied by an electromagnetic wave on a perfectly absorbing surface equals the energy density of the wave. The wave's momentum also gets transferred to the surface when an electromagnetic wave is entirely absorbed by it. The rate at which momentum is transmitted to an absorbing surface perpendicular to the propagation direction equals the force on the surface.
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
394