微升滴的重力测量沉积与放射测量确认
Denis E Bergeron1, Richard Essex1, Svetlana Nour1
1National Institute of Standards and Technology, 100 Bureau Dr., Stop 8462, Gaithersburg, MD, 20899-8462, USA.
概括
这项研究介绍了一种精确的手动微升重力度计分剂技术,使用修改后的微型管. 该方法确保准确的液体闪源准备与最小的活动损失,通过放射测量验证.
科学领域:
- 计量学 计量学 计量学
- 放射化学 放射化学是指辐射化学.
- 分析化学 分析化学
背景情况:
- 在各种科学领域中,准确地分配小液体体积至关重要.
- 重力测量方法提供高精度,但需要仔细的校准和控制.
- 放射性验证对于量化发放的放射性材料至关重要.
研究的目的:
- 为了演示一个手动微升重力度分配技术准备液体闪光源.
- 为了验证配方方法的准确性和精确性,使用一个具有良好的特征的放射性源.
- 为该技术提供全面的测量方程和不确定性分析.
主要方法:
- 修改了标准的微导管器,以便使用可拆卸的微毛细管.
- 使用241Am参考溶液制备液体闪源.
- 放射测量给药质量的测定,以验证准确性.
- 在金上分发滴滴的重力测量分析.
主要成果:
- 控制的微升体积的分配,损失最小 (≤0.34~4) %的总滴活动).
- 成功通过放射测量验证与241Am标准相对应的分配质量.
- 开发一个详细的测量方程,考虑蒸发和不确定性.
结论:
- 手动微升重力度分配技术对于准备放射性源来说是准确和可靠的.
- 该方法最大限度地减少了样本损失,这对于高活性或贵重材料至关重要.
- 提出的测量方程和不确定性分析为该技术的应用提供了坚实的框架.
更多相关视频
相关概念视频
Precipitation Gravimetry
6.7K
Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
6.7K
Gravimetry: Overview
6.0K
Gravimetric analysis is a quantitative method where the analyte is isolated and weighed directly or after conversion into a substance of known composition. Gravimetric analysis can be classified as precipitation, electrogravimetry, volatilization, and particulate gravimetry, based on the method used to isolate the analyte.
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
6.0K
Washing, Drying, and Ignition of Precipitates
947
After filtration, the precipitate is washed to remove coprecipitated impurities and any remaining mother liquor. Colloidal precipitates, such as silver chloride, are washed with an electrolyte (such as dilute nitric acid) to prevent the peptization of the precipitate. In the case of slightly soluble precipitates, the wash solution contains a common ion to reduce solubility. Lead sulfate, which is slightly soluble in water, is washed with dilute sulfuric acid. Similarly, wash solutions may be...
947
Volatilization
417
Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
417
Microbial Growth Measurement: Indirect Methods
60
Estimating microbial growth is essential for understanding population dynamics and environmental adaptations. Indirect methods provide valuable insights by measuring parameters such as turbidity, metabolic activity, and biomass, enabling efficient and reproducible assessments.During exponential growth, microbial cells scatter light proportionally to their biomass, a principle used in turbidity measurements. About one million cells per milliliter produce detectable scattering, which a...
60
Precipitation Titration: Endpoint Detection Methods
1.8K
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
1.8K