-4的佩宁陷质量测量
S Sasidharan1,2,3, O Bezrodnova1, S Rau1
1Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany.
Physical review letters
|September 18, 2023
概括
研究人员使用LIONTRAP设施精确测量了-4的原子质量. 这种新的,高度准确的-4的质量值与当前的文献值有很大差异.
科学领域:
- 原子物理 原子物理
- 计量学 计量学 计量学
- 核物理 核物理 核物理
背景情况:
- 精确的原子质量测量对于测试物理理论和建立基本常数至关重要.
- 之前对-4原子质量的测量已经达到很高的精度,但可能存在差异.
研究的目的:
- 以前所未有的精度确定-4 ($^{4}$He) 的原子质量.
- 为$^{4}$He原子质量提供一个独立的,高精度的值,以与现有数据和理论预测进行比较.
主要方法:
- 使用光离子陷 (LIONTRAP) 装置,这是一个高精度的Penning-trap质谱仪.
- 测量了 $^{4}$He$^{2+}$ 离子的质量,精确度为每万亿分之12的部分.
- 从离子质量测量计算中性 $ ^ {4} $ He 原子质量.
主要成果:
- 报告了对$^{4}$He$^{2+}$离子质量的测量:m($^{4}$He$^{2+}$) =4.001506179651(48) u.
- 确定中性 $^{4}$He 的原子质量: m($^{4}$He) =4.002603254653(48) u.
- 新的测量比CODATA18值稍微准确一些.
结论:
- 确定 $^{4}$He 的原子质量与 CODATA18 的值偏离了 6.6 个标准偏差.
- 这种显著的偏差需要进一步调查,可能表明需要重新评估当前的原子质量数据或理论模型.
- 取得的高精度凸显了LIONTRAP设备对于基本常数测量的能力.
相关概念视频
Nuclear Binding Energy
12.5K
The difference between the calculated and experimentally measured masses is known as the mass defect of the atom. In the case of helium-4, the mass defect indicates a “loss” in mass of 4.0331 amu – 4.0026 amu = 0.0305 amu. The loss in mass accompanying the formation of an atom from protons, neutrons, and electrons is due to the conversion of that mass into energy that is evolved as the atom forms. The nuclear binding energy is the energy produced when the atoms’ nucleons...
12.5K
Mass Analyzers: Common Types
642
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
642
Thomson's e/m Experiment
3.8K
In a beam of charged particles created by a heated cathode, the particles move at different speeds. However, many applications need a beam with uniform particle speeds. An arrangement known as a velocity selector uses electric and magnetic fields to pick particles with a particular speed from the beam.
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The...
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The...
3.8K
High-Resolution Mass Spectrometry (HRMS)
1.4K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.4K
Atomic Nuclei: Nuclear Spin State Population Distribution
1.0K
Near absolute zero temperatures, in the presence of a magnetic field, the majority of nuclei prefer the lower energy spin-up state to the higher energy spin-down state. As temperatures increase, the energy from thermal collisions distributes the spins more equally between the two states. The Boltzmann distribution equation gives the ratio of the number of spins predicted in the spin −½ (N−) and spin +½ (N+) states.
1.0K
Mass Analyzers: Overview
716
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
716


