变量混合与theta发射器质谱学:根据发射器位置改变溶液流速
Casey J Chen1, Evan R Williams1
1Department of Chemistry, University of California, Berkeley, California 94720, United States.
Analytical chemistry
|September 20, 2023
概括
在质谱学中,仔细定位泰达玻璃发射器对于控制溶液混合和滴滴组成至关重要. 精确的发射器放置确保了反应动力学和试剂度的准确测量.
科学领域:
- 分析化学 分析化学
- 物理化学 物理化学
背景情况:
- 泰达玻璃发射器可以快速混合溶液进行分析.
- 控制相对流速对于电喷离子化质谱学 (ESI-MS) 中可重现的结果至关重要.
研究的目的:
- 为了研究泰达玻璃发射器定位对溶液混合和滴滴组成的影响.
- 展示一种控制试剂度和研究反应动力学的方法.
主要方法:
- 使用泰达玻璃发射器来快速混合溶液.
- 在产品分析中使用电喷射电离质谱仪 (ESI-MS).
- 系统地改变发射器尖端相对于质谱仪入口的位置.
主要成果:
- 发射器的位置显著改变相对流量,变化高达三级.
- 蛋白质电荷状态 (肌球蛋白) 从 +7.8 变为 +13.8,硫氨酸度变化.
- 基于发射器位置,双分子反应转换比率从0.98变为0.04.
结论:
- 滴滴组合对泰达玻璃发射器位置非常敏感.
- 准确的动力学研究和可重复的ESI-MS实验需要精确控制发射器的位置.
- 这种方法允许使用单个发射器设置对各种溶液度的反应动力学进行研究.
相关概念视频
Atomic Emission Spectroscopy: Interference
223
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
223
Electrospray Ionization (ESI) Mass Spectrometry
908
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
908
Atomic Emission Spectroscopy: Instrumentation
520
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
520
Mass Analyzers: Common Types
642
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
642
Tandem Mass Spectrometry
1.1K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.1K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
515
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
515