相关实验视频
Updated: Jul 16, 2025

04:48
Swin-PSAxialNet: An Efficient Multi-Organ Segmentation Technique
Published on: July 5, 2024
439
进化神经架构搜索,结合多分支ConvNet和改进的变压器
1College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou, 730070, China.
Scientific reports
|September 22, 2023
概括
本研究介绍了一种使用变压器和ConvNets自动设计高效深度学习模型的进化神经架构搜索 (ENAS) 方法. 这种方法提高了性能,并降低了复杂网络架构的计算成本.
科学领域:
- 计算机科学 计算机科学
- 人工智能的人工智能
- 机器学习 机器学习
背景情况:
- 深层卷积神经网络 (CNN) 的手动设计是具有挑战性的,因为它具有复杂的拓.
- 现有的神经架构搜索 (NAS) 方法经常面临高计算成本或设计不灵活性.
研究的目的:
- 为设计CNN架构提出一种高效灵活的自动化方法.
- 为了解决当前NAS技术的局限性.
主要方法:
- 开发了一个进化神经架构搜索 (ENAS) 框架,将改进的变压器与多分支卷积神经网络 (ConvNet) 集成.
- 引入了一种新的"无批量规范化变压器块" (BFNTBlock),结合无批量规范化 (BFN) 和批量规范化 (BN),以改善特征表示和减轻估计转移.
- 多分支区块增强了功能空间丰富性和网络代表能力.
主要成果:
- 拟议的ENAS方法在CIFAR10上实现了97.24%的高精度,在CIFAR100上达到80.06%.
- 该方法表现出高计算效率,只需要1.46和1.53个GPU天进行CIFAR10和CIFAR100的训练.
- 与常见方法相比,在真实世界数据集 (GTSRB和NEU-CLS) 上观察到更高的性能,验证了其普遍性.
结论:
- 提出的ENAS方法有效地自动化了高性能和计算效率高的深度神经网络的设计.
- BFNTBlock设计证明有利于利用本地和远程依赖,同时提高模型稳定性.
- 该方法在各种计算机视觉任务中显示出强大的概括能力.
相关概念视频
Neural Circuits
1.3K
Neural circuits and neuronal pools are two of the main structures found in the nervous system. Neural circuits are networks of neurons that work together to carry out a specific task or process. They consist of interconnected neurons and glial cells, which provide structural and metabolic support.
Neuronal pools are collections of nerve cells with similar functions and interact through chemical and electrical signals. These pools include both interneurons (the central neural circuit nodes that...
Neuronal pools are collections of nerve cells with similar functions and interact through chemical and electrical signals. These pools include both interneurons (the central neural circuit nodes that...
1.3K
Types Of Transformers
1.0K
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
1.0K
Multi-input and Multi-variable systems
122
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence...
In the absence...
122
The Ideal Transformer
419
In single-phase two-winding transformers, two windings are coiled around a magnetic core characterized by cross-sectional area A and magnetic permeability μ. A phasor current i1 enters the left winding while i2 exits the right winding, establishing the fundamental working of the transformer through electromagnetic principles.
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
419
Transformers in Distribution System
118
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
118
Transformers with Off-Nominal Turns Ratios
173
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
173