热磁粒子成像技术的波依赖性
Thinh Q Bui1, Mark-Alexander Henn2,3, Weston L Tew2
1National Institute of Standards and Technology, Gaithersburg, MD, 20895, USA. thinh.bui@nist.gov.
Scientific reports
|September 22, 2023
概括
这项研究引入了一种新的磁粒子成像 (MPI) 方法,用于使用氧化铁纳米粒子进行精确的3D温度监测. 这项研究量化了成像分辨率如何取决于温度和数,从而提高了MPI的准确性.
科学领域:
- 生物医学工程 生物医学工程
- 纳米技术纳米技术
- 医疗成像医学成像
背景情况:
- 准确的现场3D温度监测对于各种应用,包括医学诊断和研究至关重要.
- 目前的磁粒子成像 (MPI) 技术需要在仪器仪表和追踪材料方面取得进展,以提高灵敏度和定位.
研究的目的:
- 开发和验证一个高分辨率的MPI仪器,用于灵敏,准确和本地化的3D温度监测.
- 为了研究MPI成像分辨率,温度和数之间的关系.
主要方法:
- 开发一个高分辨率的MPI仪器.
- 实施一种低噪音的多锁定检测方法.
- 使用铁氧化物纳米颗粒标记器来量化温度的和比方法的应用.
主要成果:
- 证明了使用MPI观察和量化温度变化的能力.
- 确定并量化了MPI成像分辨率对数和温度的依赖.
- 通过实验和模拟研究验证了MPI成像分辨率依赖于数的基本起源.
结论:
- 开发的MPI方法使得灵敏且准确的3D温度监测成为可能.
- 了解数对成像分辨率的影响是优化MPI温度映射性能的关键.
- 这项工作推进了MPI用于局部局部温度测量的能力.
相关概念视频
Paramagnetism
2.5K
Paramagnets are materials with unpaired electrons that possess a finite magnetic moment. In the absence of a magnetic field, these moments are randomly oriented, and thus the net moment is zero. Under an external field, a torque acting on the moments tends to align them along the field's direction. However, the random thermal motion of electrons produces a torque opposite to the external field and tries to disorient the moments. These two competing effects align only a few moments along the...
2.5K
Atomic Nuclei: Magnetic Resonance
681
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
681
Atomic Nuclei: Nuclear Relaxation Processes
676
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
676
Atomic Nuclei: Nuclear Spin State Population Distribution
1.0K
Near absolute zero temperatures, in the presence of a magnetic field, the majority of nuclei prefer the lower energy spin-up state to the higher energy spin-down state. As temperatures increase, the energy from thermal collisions distributes the spins more equally between the two states. The Boltzmann distribution equation gives the ratio of the number of spins predicted in the spin −½ (N−) and spin +½ (N+) states.
1.0K
Magnetic Susceptibility and Permeability
1.2K
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
1.2K
Magnetic Resonance Imaging
5.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.2K