相关实验视频
Updated: Jul 15, 2025

07:47
Measuring Delay Discounting in Humans Using an Adjusting Amount Task
Published on: January 9, 2016
15.4K
使用离散选择实验的血压远程监测程序的偏好和支付意愿
Ian Yi Han Ang1, Yi Wang2, Shilpa Tyagi2,3
1Saw Swee Hock School of Public Health, National University of Singapore and National University Health System, Singapore, Singapore. yha2103@columbia.edu.
NPJ digital medicine
|September 25, 2023
概括
患有高血压的患者更喜欢使用蓝牙功能远程监测血压 (BP). 然而,一些人对远程咨询有抵抗力,更喜欢面对面的访问.
科学领域:
- 医疗保健服务研究 医疗服务研究
- 数字健康数字健康
- 高血压管理 高血压管理
背景情况:
- 远程监测为管理高血压提供了一个有希望的方法.
- 了解患者的偏好对于成功采用远程健康计划至关重要.
研究的目的:
- 为了确定患者对血压 (BP) 远程监测程序属性的偏好.
- 确定影响这些偏好和支付意愿的因素.
- 调查是否存在抗电话咨询的子组.
主要方法:
- 对患有高血压的参与者进行了一项离散选择实验 (DCE).
- 参与者根据咨询模式,BP机器类型 (蓝牙),价格,月费和持续时间评估了BP远程监控程序.
- 分析了人口因素和数字技能对选择的影响.
主要成果:
- 一般人群更喜欢远程咨询,支持蓝牙的BP机器,更低的价格,更低的月费和更短的节目时间.
- 确定了一个对电话咨询有抵抗力的子组,与女性性别,教育程度较低和收入较低有关.
- 支付意愿估计为蓝牙的66个SGD和电话咨询的6.80个SGD/月.
结论:
- 高血压患者在监测计划中强烈偏爱远程咨询和蓝牙BP机器.
- 一个重要的子组仍然抵制远程咨询,更喜欢传统的面对面咨询.
- 这些发现有助于设计和实施以患者为中心的远程监控服务.
相关概念视频
Errors occurring during blood pressure monitoring
755
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
755
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K
Measurement of Blood Pressure
1000
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1000
Assessment of blood pressure in brachial artery(two-step method)
743
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
743
Sites for measruring blood pressure
1.8K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.8K
Assessment of blood pressure in brachial artery(one-step method)
626
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
626

