电阻谱学阻抗-读出集成电路:方法论审查
IEEE transactions on biomedical circuits and systems
|September 26, 2023
概括
本综述涵盖用于电阻谱学 (EIS) 的阻抗读取集成电路 (IC). 它详细介绍了便携式,可穿戴式和可植入式EIS系统的IC方面的进展,重点关注能源效率和性能.
科学领域:
- 电气工程 电气工程
- 生物医学工程 生物医学工程
- 材料科学 材料科学 材料科学
背景情况:
- 电阻谱学 (EIS) 系统越来越多地集成到便携式,可穿戴式和可植入式设备中,为物联网 (IoT) 时代提供服务.
- 芯片上EIS系统的性能非常依赖于负责阻抗读出的集成电路 (IC).
- 关键性能指标,包括频率范围,功耗,精度,检测范围和吞吐量,都受到读取IC设计的重大影响.
结论:
- 阻抗读取IC的进步对于未来开发用于物联网和生物医学应用的复杂EIS系统至关重要.
- 未来的研究应该专注于进一步提高能源效率,扩大频率范围,提高各种电极接口的读取IC的稳定性.
- 高性能阻抗读出IC的集成将使更容易获得和更强大的点的护理诊断和健康监测解决方案.
更多相关视频
09:36In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
8.8K
12:30Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
Published on: March 28, 2014
58.4K
相关概念视频
Impedances and Admittance
716
In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
716
RLC Series Circuits: Impedance
2.2K
When current flow is opposed in a DC or AC circuit, it is referred to as resistance or impedance, respectively. Impedance plays a key role in determining the performance of AC circuits. It is represented by Z, which is a combination of resistance and reactance, and depends upon the angular frequency, measured in ohms.
Thus, the magnitude of the impedance is given by the following equation,
Thus, the magnitude of the impedance is given by the following equation,
2.2K
Interfacial Electrochemical Methods: Overview
280
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
280
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
253
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
253
Atomic Absorption Spectroscopy: Interference
813
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
813
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K