电力变电站设备柜中与终端块相关的不规则组件的识别方法
Weiguo Cao1, Zhong Chen1, Xuhui Deng2
1School of Electrical Engineering, Southeast University, Nanjing 210096, China.
Sensors (Basel, Switzerland)
|September 28, 2023
概括
本研究介绍了一种自动化方法,用于识别智能变电站中的终端块组件,使用先进的AI模型,如YOLOv7和PaddleOCR. 这一创新显著提高了检查效率和准确性,减少了手工劳动和潜在的错误.
科学领域:
- 电气工程 电气工程
- 计算机视觉 计算机视觉
- 人工智能的人工智能
背景情况:
- 智能变电站依赖于终端块组件的手动检查,这是低效的,容易出现人为错误.
- 目前对变电站设备柜的检查方法耗时,需要大量的人力资源.
研究的目的:
- 为智能变电站开发一个自动化终端块组件检测和识别方法.
- 提高变电站设备检查流程的效率和准确性.
主要方法:
- 一个多阶段的识别系统,集成了精简的You Only Look Once版本7 (YOLOv7) 模型,微分二元化 (DB) 和PaddleOCR.
- 开发YOLOv7面积定向 (YOLOv7-AO) 系统,用于精确的终端块定位和紧的面积提取.
- 集成DB细分头部和注意力机制 (YOLOv7-DBAH) 来处理密集和不规则的组件,然后使用OCR进行身份匹配.
主要成果:
- 该YOLOv7-AO型号实现了高检测准确度,运行速度快4.45倍,并具有良好的便携性.
- YOLOv7-DBAH模型表现出卓越的性能,F1得分从0.83增加到0.89,精度超过0.91.
- 拟议的方法成功地识别了终端块组件,显示了实际适用性.
结论:
- 开发的自动化方法显著提高了智能变电站终端块组件检查的效率和准确性.
- 将YOLOv7变体与DB和OCR集成,为工业环境中复杂的组件识别任务提供了强大的解决方案.
- 该系统适合实际应用,为现代化变电站维护提供了有价值的工具.
相关概念视频
Insulation Coordination
167
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
167
Instrument Transformers
102
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
102
Circuit Breaker and Fuse Selection
121
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
121
Power System Three-Phase Short Circuits
103
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
103
Transformers in Distribution System
118
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
118
Three-Phase Short Circuit—Unloaded Synchronous Machine
160
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
160