在现实条件下仪器变压器的表征:单一和组合影响量对其宽带行为的影响
Palma Sara Letizia1, Gabriella Crotti1, Alessandro Mingotti2
1Istituto Nazionale di Ricerca Metrologica (INRIM), Strada delle Cacce 91, 10135 Torino, Italy.
Sensors (Basel, Switzerland)
|September 28, 2023
概括
仪表变压器 (IT) 对电网至关重要. 这项研究显示,在扭曲的电网条件下,温度和负载显著影响了感应电压变压器的准确性.
科学领域:
- 电气工程 电气工程
- 计量学 计量学 计量学
- 电力系统 电力系统
背景情况:
- 仪表变压器 (IT) 对于监控和测量电力系统中的电量至关重要.
- 使用可再生能源,转换器和电动汽车的现代电网引入了扭曲的电压和电流条件.
- 传统的IT绩效分析通常假定名义电网条件,而不考虑这些新挑战.
研究的目的:
- 分析仪表变压器在现实的中压电网中扭曲的电压和电流条件下的性能.
- 量化各种影响量及其对ITs的组合引起的测量误差.
- 调查环境和操作因素对IT准确性的影响.
主要方法:
- 国家计量研究所和大学之间的合作研究.
- 在现实的扭曲电网条件下检查电流和电压变压器.
- 影响大量的分析,包括温度,机械振动,负荷,相邻相和近距离效应.
主要成果:
- 发现温度和负载对感应电压变压器性能产生了最显著的影响,特别是在较低的温度下.
- 这些因素导致了比率误差和相位移的显著变化.
- 由于设计的多样性,预测相邻阶段和近距离对低功率IT频率响应的影响是复杂的.
结论:
- 信息技术性能受到非名义条件,特别是温度和负载的显著影响.
- 在现代,扭曲的电网中进行准确的测量需要对这些影响量有更深入的了解.
- 需要进一步的研究,以解决低功耗IT的复杂性,涉及到近距离和相邻相位效应.
相关概念视频
Instrument Transformers
102
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
102
Three-Winding Transformers
252
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
252
Transformers with Off-Nominal Turns Ratios
173
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
173
Equivalent Circuits for Practical Transformers
460
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
460
Transformers
1.1K
A device that transforms voltages from one value to another using induction is called a transformer. A transformer consists of two separate coils, or windings, wrapped around the same soft iron core. However, they are electrically insulated from each other.
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
1.1K
The Ideal Transformer
419
In single-phase two-winding transformers, two windings are coiled around a magnetic core characterized by cross-sectional area A and magnetic permeability μ. A phasor current i1 enters the left winding while i2 exits the right winding, establishing the fundamental working of the transformer through electromagnetic principles.
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
419