全场OCT和光传输断层扫描的比较分析
Samer Alhaddad1, Olivier Thouvenin1, Martine Boccara2
1Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 rue Jussieu, 75005 Paris, France.
Biomedical optics express
|October 4, 2023
概括
这项研究比较了光学连贯断层扫描 (OCT) 和光传输断层扫描 (OTT) 的成像. 优化的照明增强了OTT对比度和分区,展示了各种生物样本的优势.
科学领域:
- 生物医学光学 生物医学光学
- 断层成像扫描图像成像技术
- 光学物理学的光学物理.
背景情况:
- 时间域全场光学连贯断层扫描 (FFOCT) 和光传输断层扫描 (OTT) 是关键的成像方式.
- 对比它们的性能和优化参数对于推进生物成像至关重要.
研究的目的:
- 为了比较FFOCT和OTT使用一种新的组合光学设置.
- 研究用于优化OTT性能的照明调节.
- 在静态和动态生物成像应用中评估这两种方法.
主要方法:
- 开发一个新的光学设置,集成FFOCT和OTT.
- 对OTT的照明参数进行系统分析.
- 细胞培养,组织和生物体的比较成像.
主要成果:
- 前向散射特性影响了OTT轴切割和对比度.
- 照明调整显著优化了OTT性能.
- FFOCT和OTT在形态学和代谢对比成像方面表现出互补的优势.
结论:
- 结合的FFOCT-OTT系统提供了多功能的断层成像功能.
- 优化照明对于最大限度地发挥OTT的潜力至关重要.
- 这两种技术都为生物结构和动态提供了宝贵的见解.
相关概念视频
Computed Tomography
4.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.6K
Imaging Studies III: Computed Tomography
13
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
13
Phase Contrast and Differential Interference Contrast Microscopy
8.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.2K
Imaging Biological Samples with Optical Microscopy
4.8K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
4.8K
Total Internal Reflection Fluorescence Microscopy
5.8K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.8K


