光传感器用于成像间歇性
Ariel A Valiente-Gabioud1, Inés Garteizgogeascoa Suñer2, Agata Idziak3
1Max Planck Institute for Biological Intelligence, Tools for Bio-Imaging, Am Klopferspitz 18, 82152, Martinsried, Germany.
Nature communications
|October 5, 2023
概括
研究人员开发了GreenT-ECs,新型生物传感器,用于监测细胞外液体中的水平. 这些传感器可以实时跟踪活体中的组织间歇性调节.
科学领域:
- 生理学 生理学 生理学
- 生物化学 生物化学
- 神经科学是一个神经科学.
背景情况:
- 间歇性流体对于系统生理学和细胞进入至关重要.
- 在活体组织的狭窄细胞间空间中监测是具有挑战性的.
研究的目的:
- 开发高性能,超低亲和度的基因编码生物传感器.
- 为了能够监测细胞外有机体液中的度.
主要方法:
- 开发了具有很大的光变化和低结合亲和度 (0.82.9 mM) 的GreenT-ECs.
- 在动物海马神经元和体内转基因斑马鱼中的验证.
主要成果:
- 绿色T-ECs成功监测了组织间歇性的恒常调节.
- 传感器显示出适用于记录大型过渡的适用性.
结论:
- 绿色T-EC是在细胞间结构中成像平衡的有效工具.
- 这些生物传感器推进了对活组织和生物体中细胞外动态的研究.
相关概念视频
Light Acquisition
In order to produce glucose, plants need to capture sufficient light energy. Many modern plants have evolved leaves specialized for light acquisition. Leaves can be only millimeters in width or tens of meters wide, depending on the environment. Due to competition for sunlight, evolution has driven the evolution of increasingly larger leaves and taller plants, to avoid shading by their neighbors with contaminant elaboration of root architecture and mechanisms to transport water and nutrients.
Photoelectric Effect
When light of a particular wavelength strikes a metal surface, electrons are emitted. This is called the photoelectric effect. The minimum frequency of light that can cause such emission of electrons is called the threshold frequency, which is specific to the metal. Light with a frequency lower than the threshold frequency, even if it is of high intensity, cannot initiate the emission of electrons. However, when the frequency is higher than the threshold value, the number of electrons ejected...
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Imaging Biological Samples with Optical Microscopy
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Electronic Distance Measuring Instruments
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...


