免疫标记在免疫质谱成像过程中扰乱了内源和抗体结合的元素度
Monique G Mello1, Mika T Westerhausen1, Thomas E Lockwood1
1Hyphenated Mass Spectrometry Laboratory, Faculty of Science, University of Technology Sydney, P.O. Box 123, Broadway, NSW, 2007, Australia.
Analytical and bioanalytical chemistry
|October 6, 2023
概括
免疫质谱成像 (LA-ICP-MS) 显示,抗体标记会改变组织中的内源金属水平 (Cu, Zn). 有机安装介质比水性介质更好地保存元素标签.
科学领域:
- 生物医学成像学 生物医学成像学
- 分析化学是一种分析化学.
- 材料科学 是一种材料科学.
背景情况:
- 免疫质谱成像 (LA-ICP-MS) 能够对生物分子和内源元素进行多重量化量化.
- 样品的处理,包括免疫标记和盖子的滑落,可以影响组织部分的元素组成.
- 了解这些影响对于准确地进行生物分子和金属的空间分析至关重要.
研究的目的:
- 调查免疫标记和覆盖粘贴对内源金属度 (Cu, Zn) 和合抗体信号的影响.
- 评估不同安装介质对元素标签完整性的影响.
- 为优化免疫质谱成像中的样本准备提供指导.
主要方法:
- 用冷固定的肌肉部分进行分析.
- 用Gd结合抗素抗体进行免疫标记.
- 使用LA-ICP-MS量化了Gd,Cu和Zn的元素度.
- 对比了有机和水性安装介质对Gd信号的影响.
主要成果:
- 主要抗体潜伏降低了 Zn 和增加了 Cu 度, Zn 从细胞质再分配到细胞膜.
- 在抗体化后,Cu主要局限于细胞膜.
- Gd结合抗体信号没有受到有机安装介质的显著影响.
- 水性安装介质显著降低了Gd信号.
结论:
- 免疫标记的步骤改变了内源元素度和组织部分的分布.
- 建议分开部分用于内源元素和生物分子的定量分析.
- 有机安装介质是水性介质的首选,以保持基本标签完整性,在覆盖接用于补充成像.
相关概念视频
Immunogold Electron Microscopy
4.1K
Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
4.1K
Immunofluorescence Microscopy
10.6K
A fluorescence microscope uses fluorescent chromophores called fluorochromes, which can absorb energy from a light source and then emit this energy as visible light. Fluorochromes include naturally fluorescent substances (such as chlorophylls) and fluorescent stains that are added to the specimen to create contrast. Dyes such as Texas red and FITC are examples of fluorochromes. Other examples include the nucleic acid dyes 4’,6’-diamidino-2-phenylindole (DAPI), and acridine orange.
10.6K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
500
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
500