中国电力供应链的低碳未来:关键部门的识别和场景分析
1School of Economics and Management, China University of Geosciences, Beijing, 100083, China.
Journal of environmental management
|October 7, 2023
概括
中国中国中国中国.
科学领域:
- 环境科学 环境科学
- 能源政策 能源政策
- 工业生态学 工业生态学
背景情况:
- 电力行业是全球碳排放的主要来源.
- 在中国电力部门,供应链范围内的碳减排的省级战略尚未明确.
- 了解上游排放驱动因素对于有效的脱碳至关重要.
研究的目的:
- 确定推动中国电力供应链碳排放的关键上游部门.
- 分析不同电力政策在第十四个五年计划 (FYP) 期间对供应链排放的影响.
- 为省级政府提供有关低碳电力部门转型的见解.
主要方法:
- 综合多区域输入-输出分析与基于间隙的方法.
- 使用煤炭发电机组的点源数据来准确的分类输入输出表.
- 进行了用于政策影响评估的场景分析.
主要成果:
- 在其燃煤发电部门中,中国西北地区的体现碳强度最高 (36.3982.10/10000 CNY).
- 在第十四个年度期间将电力部门转移到中国西部,可能会抵消结构性电力系统变化的减排努力.
- 关键的传输部门需要提高效率,主要的排放部门需要加强低碳技术.
结论:
- 针对关键上游部门和提高效率对于低碳电力供应链至关重要.
- 省级政府需要量身定制的战略来应对电力部门脱碳的复杂性.
- 政策干预必须考虑区域差异和发电的碳强度.
相关概念视频
Power System Three-Phase Short Circuits
96
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
96
Power System Distribution
246
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
246
Transformers in Distribution System
109
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
109
What is Climate?
18.6K
Climate refers to the prevailing weather conditions in a specific area over an extended period. As the saying goes, “Climate is what you expect. Weather is what you get.” Climate is influenced by geographic factors, such as latitude, terrain, and proximity to bodies of water.
18.6K
Electrical Power
3.1K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Secondary Distribution
90
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
90