湿:

Christina Giger-Lange1, Karin Rattenbacher-Kiser, Jessica Di Lanzo

  • 1From the Institute of Medical Engineering, Lucerne University of Applied Sciences and Arts, Lucerne, Switzerland (Giger-Lange, Rattenbacher-Kiser, Di Lanzo, Di Nardo, Ille); Departement of Ophthalmologie, Medical University of Vienna, Vienna, Austria (Menapace).

概括

一个新的Formalin象限模型允许客观测试法可化仪器. 这种经过验证的湿实验室模型有效地模拟了白内障密度,使得在临床试验之前能够快速进行仪器评估.