灵活的阵列线圈用于3.0特斯拉的宫和脊外 (FACE) MRI
Frederik Abel1, Ek T Tan1, Martijn Lunenburg2
1Hospital for Special Surgery, 535 East 70th Street, NY 10021, United States of America.
Physics in medicine and biology
|October 10, 2023
概括
一个新的灵活的MRI线圈阵列显著改善了宫脊椎成像的信号噪声比. 这种合规设计提高了图像质量,并允许MRI扫描中的加速度因子更高.
科学领域:
- 磁共振成像 (MRI) 是一种磁共振成像技术.
- 医疗设备工程 医疗设备工程
- 放射学 放射学是一门学科.
背景情况:
- 高分辨率的宫脊柱 (c-脊柱) 和外脊椎部MRI需要紧密适合患者的接收器线圈,以获得最佳的信号噪声比 (SNR).
- 传统的刚性c-脊柱线圈不符合个体部解剖学,导致SNR减少.
- 灵活,可调整的线圈阵列为3DMRI提供了改进SNR和更高的加速度因子的潜力.
研究的目的:
- 设计,实施和评估一种新的,符合规范的23通道灵活的仅接收阵列,用于3特斯拉 (T) 的宫和脊外 (FACE) MRI.
- 与传统的头部单元 (HNU) 线圈相比,评估FACE阵列在SNR和并行成像能力方面的性能.
- 评估FACE阵列对高分辨率c脊椎和部MRI,包括MR神经学 (MRN) 的临床实用性.
主要方法:
- 一个具有高阻抗元件的23通道合规,灵活的仅接收阵列 (FACE) 为3TMRI设计.
- 使用测量SNR和几何因子 (g-因子) 的幻象研究对传统的21通道HNU线圈进行了评估.
- 在体内成像在健康志愿者和使用高分辨率c脊椎和部MRI协议的患者进行了3T.
主要成果:
- 与HNU相比,FACE阵列在异位中心位置的平均SNR (141%-161%) 和幻影研究中的异位中心位置的平均SNR显著更高,比HNU高4%.
- 并行成像性能在R = 2x2时显示了可比的结果,但在R = 3x3时改善了g因子 (1.46-2.15) 与FACE阵列对比HNU (2.36-3.62).
- 在体内初步测试证实了使用FACE阵列进行部骨和软组织评估的同等或更高的图像质量.
结论:
- 具有高阻抗元件的合规,高度灵活的宫MRI阵列可以显著提高SNR.
- 这种新的线圈设计提高了并行成像性能,使宫成像的加速度因子更高.
- 面部阵列有可能实现更高分辨率的宫MRI,改善诊断能力.
相关概念视频
Magnetic Resonance Imaging
5.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.2K
Magnetic Field Due To A Thin Straight Wire
4.9K
Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
4.9K
Magnetic Field Due to Two Straight Wires
2.6K
Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
2.6K
Magnetic Field of a Solenoid
4.0K
A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field due to a solenoid is the vector sum of the magnetic fields due to its individual turns. Therefore, for an ideal solenoid, the magnetic field within the solenoid is directly proportional to the number of turns per unit length and the current. Conversely, the magnetic field outside the solenoid is zero.
Consider a solenoid with 100 turns wrapped around a cylinder of...
Consider a solenoid with 100 turns wrapped around a cylinder of...
4.0K
Magnetic Field Of A Current Loop
4.6K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
4.6K
Imaging Studies IV: Magnetic Resonance Imaging
11
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
11