漏洞分析和建模对可再生能源发电系统中的电压源转换器进行虚假数据注入攻击
Yankai Xing1, Guangdou Zhang1, Jian Li1
1Power System Wide-area Measurement and Control Key Laboratory of Sichuan Province, School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
ISA transactions
|October 12, 2023
概括
可再生能源的整合引入了网络风险. 本研究提出了针对电压源转换器的虚假数据注入攻击 (FDIA) 算法,证明其通过规避检测机制来破坏电网稳定的能力.
科学领域:
- 电气工程 电气工程
- 网络安全 网络安全
- 电力系统 电力系统
背景情况:
- 增加可再生能源的整合需要更多的电力电子设备,创造新的网络攻击载体.
- 电网中的等级控制系统容易受到复杂的网络威胁.
- 电压源转换器 (VSC) 是易受操纵的关键组件.
研究的目的:
- 调查分层电网控制系统的网络漏洞.
- 提出一个新的虚假数据注入攻击 (FDIA) 构建算法,针对VSC.
- 证明FDIA在绕过二次控制环中的现有检测方法方面的有效性.
主要方法:
- 开发一个专门为VSCs设计的FDIA模型.
- 使用物理攻击发生器或监督控制和数据采集 (SCADA) 系统伪造攻击的模拟.
- 整合FDIA模型与状态估计,以绕过不良数据检测.
- 在单个转换器无限总线基准和IEEE 34 总线系统上测试拟议的攻击.
主要成果:
- 拟议的FDIA模型成功欺骗了国家估计过程.
- 攻击模型有效地绕过了二级控制循环中的错误数据检测机制.
- 模拟表明,FDIA可以在电力系统中引发威胁性的振荡.
- 该攻击在一个简单的基准和一个更复杂的IEEE 34总线系统上都被证明是有效的.
结论:
- 该研究强调了与在可再生能源透率高的电网中越来越多地使用VSCs相关的重大网络安全风险.
- 开发的FDIA算法是一个可行的威胁,能够破坏电力系统的稳定.
- 需要加强安全措施,以保护VSC和二次控制循环免受这种复杂的数据伪造攻击.
相关概念视频
Power System Three-Phase Short Circuits
94
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
94
Fast Decoupled and DC Powerflow
216
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
216
Energy Losses in Transformers
885
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
885
Generator Voltage Control
162
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
162
Wind Turbine Machine Models
146
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
146
Control of Power Flow
272
There are several methods to control power flow in power systems:
272