一个对温度敏感,高粘合度的医疗磁带:一个比较的,单盲临床试验
Shawn Swanson1, Vivian Luu1, Ryan Smith1
1Human Photonics Laboratory, Department of Mechanical Engineering, University of Washington, Seattle, WA, US.
Journal of wound care
|October 13, 2023
概括
与标准带相比,加热一个新的医疗带,ThermoTape,在去除时显著减少疼痛和皮肤发红. 这一创新可以提高医疗器械的安全性,同时尽量减少皮肤创伤和伤害.
科学领域:
- 生物材料科学 生物材料科学
- 皮肤病学 皮肤病学
- 医疗器械技术 医疗器械技术
背景情况:
- 医疗粘合剂对于固定伤口带和设备至关重要.
- 高粘合性带可能会导致与医疗粘合剂相关的皮肤损伤 (MARSI),而低粘合性带可能会导致脱落.
- 需要安全的医疗磁带,在移除时尽量减少皮肤创伤.
研究的目的:
- 为了临床评估一种新型高粘度医疗带的性能,ThermoTape.
- 为了比较ThermoTape的去除特性 (疼痛,皮肤发红) 与现有的磁带 (Tegaderm,KRT).
- 评估升温对带带去除和相关皮肤创伤的影响.
主要方法:
- 进行了一项由53名受试者参与的单盲比较临床试验.
- 在健康的志愿者的前臂上涂上了ThermoTape,Tegaderm和Kind Removal Tape (KRT).
- 带在24小时后被移除,有或没有预热,并记录了带的磨损,疼痛和红色.
主要成果:
- 热带带随着升温移除,疼痛减少了58%,皮肤发红减少了45% (p<0.01).
- 加热Tegaderm和KRT没有产生疼痛或红色的统计学上显著差异.
- 与没有加热的Tegaderm (p<0.01) 相比,加热的ThermoTape显著降低了疼痛 (在Wong-Baker尺度上高于1分).
结论:
- 在去除前加热热热带显著减少疼痛和皮肤发,与标准的磁带相比.
- 这一发现表明,ThermoTape可以提供安全的设备附件,同时最大限度地减少MARSI.
- 这项研究支持ThermoTape在伤口护理和医疗器械固定方面提高患者舒适性和安全性的潜力.
相关概念视频
Equipments Used to Measure Body Temperature
1.0K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.0K
Temperature Measurement Sites
1.7K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.7K
Assessing Body Temperature - Tympanic membrane
595
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
595
Assessing Body Temperature - Temporal Artery
562
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
562
Assessing Body Temperature - Oral
750
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
750
Assessing Body Temperature - Axilla
597
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
597