通过增加流量增加增加吸收能力来提高水质管理:雅那河的案例研究,德里
Nibedita Verma1, Geeta Singh2, Naved Ahsan3
1Department of Environmental Engineering, Delhi Technological University, New Delhi, Delhi 110042, India
概括
为了改善山河流域.
科学领域:
- 环境工程 环境工程
- 水质管理水质管理
- 河流生态系统 河流生态系统
背景情况:
- 德里的亚木纳河面临着来自众多外流下水道的重大污染挑战.
- 保持足够的溶氧 (DO) 和生化氧需求 (BOD) 水平对于河流健康至关重要.
研究的目的:
- 评估必要的减负和增加流量,以提高山河的吸收能力.
- 确定污染物负载管理和水流的最佳策略,以改善水质.
主要方法:
- 使用 QUAL2kw 河流质量模型进行预测.
- 在严峻的季风前流量条件下校准和验证模型.
- 调查了四个案例中的41个场景,从16个已识别的排水道中对上游流量和污染物负载进行了不同的研究.
主要成果:
- 确定每秒80立方米 (cumecs) 的上游流量可以同化大量的生化氧需求 (BOD) 和化学氧需求 (COD) 负载.
- 实现了每天31.33BOD和142.85COD的同化.
- 在整个研究的河流段保持了所需的DO水平 (≥4 mg/L) 和BOD水平 (≤3 mg/L).
结论:
- 流量增加与战略负载减轻相结合,有效地改善了山河的水质.
- 一个特定的上游流量可以显著提高河流处理污染物的能力.
- 该研究为控制纳河污染和水资源管理干预提供了定量基础.
更多相关视频
12:50Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
11.3K
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
9.2K
相关概念视频
Quality of Water
104
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
104
Laminar Flow
1.1K
Laminar flow represents a smooth, orderly fluid motion where particles move along parallel paths, resulting in minimal mixing between layers. Streamlined particle paths characterize this flow regime and occur under conditions where viscous forces dominate over inertial forces. The distinction between laminar, transitional, and turbulent flow is primarily determined by the Reynolds number, a dimensionless quantity calculated as:
1.1K
Gradually Varying Flow
57
Gradually varying flow (GVF) in open channels describes situations where water depth changes slowly along the channel due to factors like non-uniform bed slope, channel shape variations, or obstructions. This flow type occurs when the depth adjusts gradually to balance gravitational forces, shear forces, and energy requirements, resulting in a low rate of depth change.Characteristics of Gradually Varying FlowGVF is commonly observed in natural streams, rivers, and canals, where flow depth...
57
Design Example: Design of an Irrigation Channel
109
Trapezoidal channels are widely used in irrigation systems due to their cost-effectiveness and efficiency in conveying water. Trapezoidal channels feature a flat bottom and sloping sides, making them stable and easier to construct compared to other shapes. The bottom width and side slope ratio are determined based on the required flow capacity and site conditions. The side slope is kept gentle for unlined channels to prevent soil erosion.Hydraulic parameters in channel design include the flow...
109
Regulation of Water Output
311
The human body predominantly expels water through the urinary system. On average, an individual generates around 1.5 liters of urine each day. This amount can fluctuate based on how well a person is hydrated, but a critical minimum quantity of urine must be produced to ensure the body's proper functioning. Daily, the kidneys remove 600 to 1200 milliosmoles of dissolved substances, effectively excreting excess minerals and water-soluble toxins such as creatinine, urea, and uric acid from the...
311
Testing Water Quality
119
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
119