在QCM-D实验中,人工物对光的校正诱导了调节
Philipp Ortner1, Maren Umlandt1, Nino Lomadze1
1Department of Smart Soft Matter, Institute of Physics and Astronomy, University of Potsdam, 14476 Potsdam, Germany.
Analytical chemistry
|October 13, 2023
概括
这项研究介绍了一种方法来纠正石晶微平衡与消散 (QCM-D) 测量中的光诱导的文物. 这确保了对光敏材料的准确分析,从而最大限度地减少了测量误差.
科学领域:
- 材料科学 材料科学 材料科学
- 表面科学是一门学科.
- 分析化学 分析化学
背景情况:
- 石英晶体微平衡与消耗 (QCM-D) 是一种多功能技术,用于研究界面上的表面活性物质.
- 使用QCM-D研究光敏材料是具有挑战性的,因为光诱导解调 (LID) 文物.
研究的目的:
- 为纠正光学刺激引起的QCM-D传感器响应人工物提供准则.
- 为了使用QCM-D进行对光敏感材料的定量分析.
主要方法:
- 开发了一种方法来纠正光照照射期间QCM-D传感器响应中的工件.
- 研究了影响光感应脱调 (LID) 的因素.
主要成果:
- 引入了一个简单的指导方针,用于在QCM-D测量中纠正LID文物.
- 证明LID受传感器吸附特性和溶剂特性 (离子度,粘度) 的影响.
结论:
- 开发的指南允许使用QCM-D对光敏材料进行准确的定量分析.
- 了解LID依赖性使得可以制定策略来最大限度地减少其对测量的影响.
相关概念视频
NMR Spectrometers: Resolution and Error Correction
705
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
705
¹H NMR: Interpreting Distorted and Overlapping Signals
1.0K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.0K
Atomic Absorption Spectroscopy: Interference
807
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
807
Double Resonance Techniques: Overview
233
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
233
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.1K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.1K
π Electron Effects on Chemical Shift: Overview
1.1K
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.1K