Irina V Alenkina1, Andrey V Chukin1, Gregory Leitus2
1Institute of Physics and Technology, Ural Federal University, Ekaterinburg 620002, Russian Federation.
Journal of pharmaceutical and biomedical analysis
|October 13, 2023
概括
铁补充剂通常含有不稳定的铁化合物,这些化合物会转化或氧化. 莫斯巴乌尔光谱检测显示了药品中铁的声明和实际状态之间的差异,突出了其对质量控制的重要性.
科学领域:
- 材料科学 材料科学 材料科学
- 分析化学 分析化学
- 制药科学 制药科学
背景情况:
- 含铁的药物广泛用于治疗缺铁性贫血.
- 这些补充剂中铁化合物的稳定性和准确成分对于有效性和安全性至关重要.
- 制造商声明可能并不总是反映产品中真正的铁状况.
研究的目的:
- 分析各种含铁制药产品中的铁状态.
- 使用先进的分析技术,将声明的铁化合物与其实际成分进行比较.
- 评估 57Fe Mössbauer 光谱对铁补充剂质量控制的有用性.
主要方法:
- 使用57Fe Mössbauer光谱仪进行详细的铁状况分析.
- 集成的X射线衍射和磁化测量用于全面的表征.
- 研究了七种不同的含铁制药产品,含有不同的铁化合物.
主要成果:
- 药品中的铁化合物被发现是不均的,存在于修改或氧化产品.
- 在分析的补充剂中检测到铁和铁铁化合物.
- 在制造商宣布的铁化合物和由Mössbauer光谱学确定的铁化合物之间观察到显著差异.
结论:
- 制药产品中铁的状态通常很复杂,并且由于不稳定性而变化.
- 57Fe Mössbauer光谱是准确评估和控制药品中铁含量的宝贵工具.
- 这种技术可以识别制造商声明中的差异,确保产品质量和治疗效果.
更多相关视频
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
8.1K
04:40Dynamic Light Scattering Analysis for the Determination of the Particle Size of Iron-Carbohydrate Complexes
Published on: July 7, 2023
2.5K
相关概念视频
Qualitative Analysis
For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
For instance, group IV...
Colors and Magnetism
Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human eye.
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human eye.
Complexometric Titration: Overview
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free indicator. The...