对外墙材料类型对窗与墙接口的热桥的影响分析
1Department of Civil Engineering, Faculty of Civil Engineering, Czestochowa University of Technology, 69 Dabrowskiego St., 42-201 Czestochowa, Poland.
Materials (Basel, Switzerland)
|October 14, 2023
概括
在绝缘层中正确安装窗户可以显著减少建筑的热量损失和能源需求. 这种方法可使年度供暖需求降低至少10%,提高能源效率.
科学领域:
- 建筑科学 建筑科学
- 热力工程是热力工程中的一个.
- 可持续的建筑 可持续的建筑
背景情况:
- 提高建筑物的能源效率至关重要,但在最小化窗户到墙壁接口的热损失方面仍然存在挑战.
- 节能需求不断增加,需要在窗户周围的热桥解决方案.
研究的目的:
- 展示正确的窗户安装和材料选择对建筑能效的优势.
- 分析窗户放置在绝缘层和墙壁材料特性对热性能的影响.
主要方法:
- 进行了用于供暖和冷却的建筑能耗分析.
- 使用TRISCO软件进行了热和湿度模拟.
- 使用Audytor OZC软件进行了节能经济分析.
主要成果:
- 在隔热层内分析了一种新的窗户安装系统.
- 这种安装方法使每年供暖需求平均减少了至少10%.
结论:
- 窗户安装方法和墙壁材料类型相互依赖,需要同时考虑.
- 优化选择可以减少建筑物供暖/冷却的能源消耗,降低成本,减少温室气体排放.
相关概念视频
Thermal Insulation in Masonry Walls
128
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
128
Conduction, Convection and Radiation: Problem Solving
1.3K
There are three methods by which heat transfer can take place: conduction, convection, and radiation. Each method has unique and interesting characteristics, but all three have two things in common: they transfer heat solely because of a temperature difference; and the greater the temperature difference, the faster the heat transfer.
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
1.3K
Cavity Drainage and Flashings in Masonry walls
91
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
91
Composite Masonry Walls
1.2K
Composite masonry walls combine multiple wythes of the same or different masonry materials to create a unified structure. These walls feature wythes that are bonded together either through mortar-filled collar joints, grouted spaces, or more commonly, with rigid metal ties and reinforcements, with the use of masonry header units being rare. Metal ties are preferred because they effectively minimize water penetration, as these walls primarily absorb moisture and then release it into the...
1.2K
Masonry Curtain Walls
1.1K
Masonry curtain walls employ brick or stone veneers supported by the building's structure to form an external cladding system that is both aesthetically appealing and functional. These walls are erected through two principal techniques, first by traditional layering of masonry units and second by using prefabricated panels. Traditional construction relies on steel shelf angles attached to the spandrel beam for support, with high-bond mortars ensuring secure attachment of masonry veneer...
1.1K
Masonry Cavity Walls
1.0K
Cavity walls feature a hollow space between the outer and inner wythes, connected only by corrosion-resistant metal ties. When water seeps through the outer wythe, it descends within this cavity, intercepted by flashing and eventually exiting through weep holes. To enhance moisture resistance, the inner wythe's cavity side often receives damp-proofing, doubling as an air barrier. The cavity can also house insulation to mitigate heat transfer.
Maintaining a clean cavity during construction...
Maintaining a clean cavity during construction...
1.0K