改进了RAKEL对高速列车引变压器的故障诊断方法
Man Li1,2,3, Xinyi Zhou1,2, Siyao Qin2
1State Key Laboratory of Advanced Rail Autonomous Operation, Beijing Jiaotong University, Beijing 100044, China.
Sensors (Basel, Switzerland)
|October 14, 2023
概括
本研究引入了一种改进的RAKEL算法,用于诊断高速列车引变压器故障,使用维护数据来提高准确性. 这种新方法提高了故障识别,有助于及时维护和提高火车安全.
科学领域:
- 工程 工程师 工程师 工程师
- 计算机科学 计算机科学
- 人工智能的人工智能
背景情况:
- 拉力变压器故障在高速列车中很常见,影响安全运行.
- 目前的故障诊断严重依赖于手工经验,这种经验效率低下,容易出现错误.
研究的目的:
- 开发一个改进的RAKEL (Random k-Labelsets) 算法,用于准确诊断高速列车引变压器的故障.
- 为了提高诊断能力,利用历史维护数据.
主要方法:
- 从维护记录中的特定监控值构建实例向量.
- 使用Relief算法提取相关故障并改善RAKEL中的k-labelset选择.
- 应用数据和错误之间的关联规则用于识别.
主要成果:
- 改进的RAKEL算法在故障诊断的评估指标中显示出显著的改进.
- 超过了其他多标签分类算法,如二进制相关性 (BR) 和校准标签排名 (CLR).
结论:
- 拟议的方法提供了一种更有效的方法来诊断高速列车的引变压器故障.
- 这可以帮助工程师及时进行维护,从而提高运营安全.
更多相关视频
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
1.9K
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
5.9K
相关概念视频
Power System Three-Phase Short Circuits
94
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
94
Three-Phase Short Circuit—Unloaded Synchronous Machine
151
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
151
Differential Relays
149
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
149
Directional Relays
126
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
126
Three-Winding Transformers
238
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
238
Series R—L Circuit Transients
105
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
105