与中国相关的细颗粒的排放和捕获特性
Wenhua Chen1, Yaxuan Xiao1, Junjie Liu2
1School of Infrastructure Engineering, Nanchang University, Nanchang, China.
Environmental science and pollution research international
|October 17, 2023
概括
中国的会释放细颗粒物,影响室内空气质量. 这项研究调查了各种方法的PM1和细颗粒排放,揭示了颗粒生成和捕获效率的差异.
科学领域:
- 环境科学 环境科学
- 室内空气质量 室内空气质量
- 气溶科学 气溶科学
背景情况:
- 是室内空气污染物的重要来源,特别是细颗粒.
- 以前的研究集中在中国中的超细颗粒 (UFP) 和PM2.5,对细颗粒大小分布的关注较少.
- 了解细颗粒的特性至关重要,因为它们主导着中国排放中的质量尺寸分布.
研究的目的:
- 为了确定来自三种中国方法的PM1和细颗粒的排放特性.
- 用修改的间接方法测量颗粒捕获效率,考虑颗粒衰变.
- 调查方法和颗粒大小对排放特征和捕获效率的影响.
主要方法:
- 分析炸,炸和炸的中国菜的PM1和细颗粒物排放量.
- 使用修改的间接方法测量颗粒捕获效率.
- 粒子大小分布 (0.542-10μm) 和衰变速率的表征.
主要成果:
- 炸的蔬菜和炸的肉类产生了更多的微粒 (0.542-1.5微米).
- 油炸和油炸的肉类菜产生了更高的PM1.
- 颗粒的衰变随着颗粒直径的增加而增加,对2-3μm颗粒的捕获效率产生约5%的影响.
- 对于PM1和0.542-5μm颗粒的捕获效率在推的排气流量下在60-90%之间.
结论:
- 方法会影响细颗粒和PM1的产生,而肉类菜往往会产生更多.
- 粒子衰变是捕获效率的一个重要因素,特别是对于较大的微粒.
- 虽然方法影响颗粒的产生,但它们对细颗粒的总体体积频率 (0.542-10μm) 的敏感性较小.
- 通过适当的排气系统,可以有效捕获与有关的细颗粒.
相关概念视频
Gas Chromatography: Types of Detectors-II
393
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
393
Atomic Absorption Spectroscopy: Atomization Methods
537
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
537
Atomic Emission Spectroscopy: Interference
203
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
203