无接触婴儿呼吸暂停检测用于预防低氧,使用K频段生物医学雷达
IEEE transactions on bio-medical engineering
|October 18, 2023
概括
这项研究介绍了一种非接触式雷达系统,用于监测婴儿的呼吸和心脏活动,这对于检测呼吸暂停 (呼吸停止) 和预防早产婴儿缺氧至关重要.
科学领域:
- 生物医学工程 生物医学工程
- 新生儿监测新生儿监测
- 雷达技术 雷达技术的使用
背景情况:
- 过早出生的婴儿经常经历呼吸暂停,导致缺氧.
- 传统的婴儿心肺监测需要与皮肤接触,限制长期使用.
研究的目的:
- 引入一种非接触式婴儿心肺监测技术.
- 开发一个可调节的呼吸暂停检测算法,以改善婴儿护理.
主要方法:
- 使用了定制的K波段连续波生物医学雷达传感器系统.
- 为雷达开发了一个自适应式数字调功能.
- 实现了一个具有自适应值和个性化呼吸暂停警告时间的算法.
主要成果:
- 成功提取了婴儿呼吸和心跳信号的非侵入性.
- 精确监测心肺信号和不同持续时间的呼吸暂停.
- 在临床环境中证明了有效的性能.
结论:
- 无接触雷达技术为婴儿心肺监测提供了一个可行的解决方案.
- 可调节的呼吸暂停检测算法增强了管理呼吸暂停事件的能力.
- 这项技术显示出临床和非临床婴儿监测应用的潜力.
相关概念视频
Pulse Oximetry
340
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
340
Equipments Used To Measure Blood Pressure
986
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
986
Assessment of apical radial pulse
755
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
755
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K