选项和Denali下静脉卡瓦过器的特点
Lihao Qin1, Xiaocheng Gu1, Kai Wang1
1Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.
Annals of vascular surgery
|October 18, 2023
概括
与Denali过器相比,可选过器在放置后倾斜更多并改变角度. 德纳利过器会导致更多的IVC收缩,而选项过器由于倾斜而需要更长的检索光镜时间.
科学领域:
- 这是血管外科手术.
- 医疗器械工程 医疗器械工程
- 放射学 放射学是一门学科.
背景情况:
- 下静脉 (IVC) 过器对于预防肺栓塞至关重要.
- 选项和Denali过器是常用的IVC过器,具有不同的设计.
- 了解它们的性能特征对于临床决策至关重要.
研究的目的:
- 为了比较Option和Denali IVC过器的放置和检索特性.
- 为了确定波器特征和患者解剖学之间的关联.
- 为了评估波器倾斜的发生率,倾斜角度变化和IVC收缩.
主要方法:
- 在2019年8月至2022年8月期间,对119名接受过器安置的患者进行了回顾性研究.
- 包括接受了Option或Denali过器的患者.
- 分析过器倾斜,倾斜角度变化,检索成功,IVC收缩和光镜时间.
主要成果:
- 与Denali过器相比,选项过器在放置后的倾斜率 (76.7%) 和倾斜角度变化 (74.1%) 显著更高 (分别为11.9%和8.3%).
- 选项过器在放置时的倾斜与常见阴道静脉-下腔静脉 (CIV-IVC) 角度相关.
- 德纳利过器在检索后的IVC收缩率 (87.5%) 比选项过器 (22.2%) 高.
- 选项波器检索需要更长的中等光镜时间,与检索期间的倾斜角度相关.
结论:
- 选项过器在放置和放置后的角度变化时更容易倾斜.
- 选项过器的倾斜角度受到CIV-IVC角度的影响.
- 选项过器检索与因倾斜而增加的光镜时间有关.
- 德纳利过器在放置后更有可能导致IVC收缩.
相关概念视频
Hemodialysis I: Introduction
36
Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
36
Venous Thrombosis III: Interprofessional Care
10
Venous thrombosis requires effective prevention and treatment strategies to improve patient outcomes and reduce potential complications.Prevention StrategiesHealthcare providers must prioritize preventing venous thromboembolism (VTE) for all adult patients upon admission. Interventions depend on bleeding and thrombosis risk, medical history, current medications, diagnoses, planned procedures, and patient preferences. Patients on bed rest should change positions every two hours and, if not...
10
Hemodialysis II: Procedure and Complications
27
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
27
Dialysis
709
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
709
Filtration
833
Filtration is a physical separation process that involves passing a suspension through a porous medium to separate solids from fluids. During filtration, solids collect on the porous medium while liquids, also collectively known as the filtrate, pass through. The filtration medium is selected based on the filtration purpose, quantity, and nature of the precipitate. The general criteria for a suitable filtering medium are that it is inert, mechanically strong, nonabsorbent toward dissolved...
833
Cardiac Catheterization I: Pre-Procedure Overview
30
Cardiac catheterization is an invasive diagnostic technique used to identify and evaluate structural and functional diseases of the heart and major blood vessels. This technique diagnoses congenital heart disease, coronary artery disease, valvular heart disease, and coronary spasms and assesses ventricular function. It helps guide treatment decisions, including the need for revascularization procedures like percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) and...
30