在具有模式依赖损失的光学SDM系统中对最佳MIMO线性接收器进行BER分析
Optics express
|October 20, 2023
概括
本研究分析了带有MIMO MMSE接收器的空间分区复杂化系统中的符号间干扰和交叉声,发现取决于模式的损失/收益影响比特错误率不可预测. 使用通用极值分布来表征性能.
科学领域:
- 视觉通信系统工程 视觉通信系统工程
- 无线和光学通信的信号处理.
- 信息理论和编码.
背景情况:
- 最小平均平方误差 (MMSE) 接收器是空间分割复杂化 (SDM) 连贯光学系统的标准.
- 模式依赖损失 (MDL) 和模式依赖增益 (MDG) 引入不可预测的符号间干扰 (ISI) 和交叉声.
- 随机的MDL/MDG对理想的MIMO MMSE接收器中的比特错误率 (BER) 的影响尚不清楚.
研究的目的:
- 为了评估MIMO MMSE接收器后的残余扭曲 (ISI和交叉声).
- 在随机的MDL/MDG条件下分析BER的概率密度分布 (PDF).
- 提出预测系统性能和中断概率的方法.
主要方法:
- 分析评估剩余的ISI和交叉通话.
- 使用单载波2PAM系统与MIMO分数间隔等分器 (FSE) 的数值模拟.
- 将BER PDF与通用极值 (GEV) 分布相匹配,并提出参数调整函数.
主要成果:
- 在MIMO MMSE接收器之后的残余扭曲的特征.
- 分析了BER PDF,并发现它符合GEV分布.
- 建议使用多项式函数将系统参数 (MDL/MDG,SNR) 与GEV PDF参数联系起来.
- 为目标中断概率生成BER的轮图.
结论:
- 该研究为分析和预测SDM光学系统与MIMO MMSE接收器在现实的通道损伤下性能提供了一个框架.
- 电力汽车分布有效地模拟随机的BER,使得更好的系统设计和性能保证.
- 拟议的轮图有助于优化系统参数以达到所需的可靠性水平.
相关概念视频
Receiver Operating Characteristic Plot
250
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
250
Beams with Symmetric Loadings
195
The moment-area method is an analytical tool used in structural engineering to determine the slope and deflection of beams under various loads. Consider a cantilever with a concentrated load and moment at the free end. The first step is constructing a free-body diagram to calculate the reactions at the fixed end. Next, the bending moment diagram is plotted to visualize how the bending moment varies along the beam's length, focusing on points where the bending moment equals zero.
The M/EI...
The M/EI...
195
Beams with Unsymmetric Loadings
123
Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
123
Lossless Lines
131
In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi,...
131
Boundary Conditions: Lossless Lines
99
Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
99
Reducing Line Loss
156
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
156