在线XRF分析仪用于测量酸盐泥中的P2O5含量
Ismail Ben Amar1,2,3, Andrew Thomas4, Claus Bachmann4
1Department of Electrical and Computer Engineering, Université Laval, Quebec City, QC, Canada. ismail.ben-amar.1@ulaval.ca.
Scientific reports
|October 20, 2023
概括
一个优化的在线X射线光 (XRF) 设置准确地分析酸盐泥 (PS) P2O5含量. 水平流配置实现了低平均绝对误差,证明了XRF.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
背景情况:
- 在酸盐泥中精确的P2O5分析对于工艺控制至关重要.
- 在线分析为化学工业的实时监控提供了优势.
研究的目的:
- 构建和优化在线X射线光 (XRF) 设置,用于酸盐泥 (PS) 中的P2O5分析.
- 评估不同的流量配置,以提高准确性和效率.
- 为在线P2O5测定确定最佳测量参数.
主要方法:
- 在线XRF设置的构建和优化.
- 使用垂直和水平流配置对酸盐泥样品的分析.
- 使用参考样本开发校准曲线.
- 测量参数的实验优化 (刺激能量,电流,距离,时间,波器).
主要成果:
- 水平流配置实现了0.38%的平均绝对误差,明显优于垂直流 (0.87%).
- 对于高达18.50%的P2O5度 (水平流) 建立了校准曲线.
- 最佳参数包括20-25kV激发能量,600μA电流,18毫米的样品探测器距离,60秒的测量时间和过器.
结论:
- 优化的在线XRF设置是确定酸盐泥中P2O5含量的可行和准确方法.
- 横流配置为此应用提供了卓越的性能.
- 对于酸盐生产中化学分析的数字化,XRF技术显得有前途.
更多相关视频
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
14.6K
06:42Measuring Phosphorus Release in Laboratory Microcosms for Water Quality Assessment
Published on: July 22, 2019
6.6K
相关概念视频
Determining the pH of Salt Solutions
The pH of a salt solution is determined by its component anions and cations. Salts that contain pH-neutral anions and the hydronium ion-producing cations form a solution with a pH less than 7. For example, in ammonium nitrate (NH4NO3) solution, NO3− ions do not react with water whereas NH4+ ions produce the hydronium ions resulting in the acidic solution. In contrast, salts that contain pH-neutral cations and the hydroxide ion-producing anions form a solution with a pH greater than 7. For...
Precipitation Gravimetry
Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation and Co-precipitation
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...