熟悉门诊睡眠和血压监测是代表性数据收集的必要条件
Kasey Kleiber1, Caroline J Smith1, Steven D Beck1
1Department of Public Health and Exercise Science, Appalachian State University, Boone, North Carolina, USA.
Physiological reports
|October 20, 2023
概括
健行睡眠和血压监测需要至少三晚的准确数据. 这使个人能够适应设备,确保可靠的睡眠架构和血压测量.
科学领域:
- 睡眠医学 睡眠医学
- 心血管生理学心血管生理学
- 生物医学工程 生物医学工程
背景情况:
- 门诊睡眠和血压监测提供了方便的家庭数据收集.
- 对于这些设备的数据可靠性和适应期的了解有限.
研究的目的:
- 为了确定睡眠架构和血压数据在门诊监测期间稳定所需的夜晚数量.
- 为了测试这个假设,熟悉监控设备发生在第三个晚上.
主要方法:
- 十名男性和十名女性受试者连续三晚同时进行睡眠和血压监测.
- 记录了睡眠结构参数 (例如,快速眼动睡眠,睡眠开始后醒来,睡眠延迟) 和血压指标.
- 统计分析比较了第一晚和第三晚的数据,以及其他相关的比较.
主要成果:
- 快速眼动 (REM) 睡眠时间的百分比在第一夜和第三夜之间有显著差异.
- 与第一天相比,第3天晚上缩压,腹缩压和脉压显著降低.
- 皮层和自主性唤醒在第3晚和第2晚分别显示出显著的差异,与第1晚相比.
结论:
- 为了熟悉和收集可靠的数据,至少需要三晚的门诊监测.
- 睡眠结构,特别是快速眼动睡眠,血压指标在三晚后稳定下来.
- 使用至少3个夜晚的数据可确保门诊睡眠和血压监测设备的研究结果的有效性和可靠性.
相关概念视频
Errors occurring during blood pressure monitoring
742
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
742
Special considerations while measuring blood pressure
729
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
729
Pre-Procedural Guidelines for Assessing Blood Pressure
574
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
574
Hypertension III: Clinical Manifestations and Diagnostic Studies
15
Hypertension is asymptomatic and also referred to as the "silent killer" until it progresses to a severe stage or causes target organ disease. Patients may experience symptoms stemming from the strain on blood vessels and tissues in various organs or the heart's increased workload.Physical exams might show no abnormalities other than high blood pressure. Signs of vascular damage, when present, correspond to the organs supplied by the affected vessels, leading to target organ damage. For...
15
Measurement of Blood Pressure
975
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
975
Equipments Used To Measure Blood Pressure
986
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
986