军团:一种用于高通量电化学的仪器
Benjamin H R Gerroll1, Krista M Kulesa1,2, Charles A Ault1
1Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States.
ACS measurement science au
|October 23, 2023
概括
一个新的高吞吐量电化学平台,Legion,可以通过96个独立控制的细胞进行快速测试. 这项创新加速了电分析和电合成,以更快地实现科学发现.
科学领域:
- 电化学 电化学 电化学
- 分析化学 分析化学
- 化学工程是化学工程的重要组成部分.
背景情况:
- 电化学方法对于科学发现至关重要.
- 当前的电化学技术可能会耗费大量时间进行广泛的测试.
- 需要高通量平台来加速研究.
研究的目的:
- 推出一个名为Legion的新型高吞吐量电化学平台.
- 展示平台在电分析和电合成方面的能力.
- 评估这种新仪器的优点和局限性.
主要方法:
- 开发一个96通道的电化学阵列 (军团).
- 通过现场可编程门阵列,独立控制每个电化学单元.
- 使用模型电化学探针进行测试,pH取决于电子转移和脱反应.
主要成果:
- 通过各种电化学测量,成功展示了Legion的功能.
- 96个细胞的独立控制允许并行实验.
- 该平台适用于电分析和电合成应用.
结论:
- 军团在电化学仪器仪表方面取得了重大进展.
- 军团的高通量性质促进了加快的假设测试.
- 这个平台有可能扩大电化学研究工具箱.
相关概念视频
Controlled-Potential Coulometry: Electrolytic Methods
178
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
178
Capillary Electrophoresis: Instrumentation
241
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
241
Potentiometry: Membrane Electrodes
596
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
596
Voltammetry: Overview
1.8K
Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
1.8K
Voltammetric Techniques: Linear-Scan (E vs Time)
412
Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
412
Voltammetry: Stripping Methods
247
Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
247