在移动平台上使用智能心电图进行患者自我监测
Malin Jakobsen1, Ankica Babic1,2
1Department of Information Science and Media Studies, University of Bergen, Bergen, Norway.
Studies in health technology and informatics
|October 23, 2023
概括
这项研究引入了使用智能心电图 (PCG) 和数字平台的远程患者自我监测系统. 该系统通过数据共享和分析提高了患者的认识,并促进了医生咨询.
科学领域:
- 生物医学工程 生物医学工程
- 数字健康数字健康
- 心脏病学 心脏病学
背景情况:
- 远程患者自我监测提供了诸如提高患者意识和便利性等好处.
- 现有的系统可能缺乏为患者和医生提供综合平台.
- 声心图 (PCG) 是用于心脏评估的有价值的诊断工具.
研究的目的:
- 设计和开发一个远程患者自我监控系统的高保真原型.
- 将智能心声学与移动和基于网络的平台集成为患者和医生使用.
- 为了使患者和医生之间能够共享数据和咨询.
主要方法:
- 开发两个不同的原型:一个为患者,一个为医生.
- 实施用户配置文件,以便为每个用户类型提供不同的功能.
- 利用智能心声学来进行信号测量和分析.
主要成果:
- 成功开发具有核心功能的患者和医生原型.
- 患者原型允许PCG信号测量和结果审查.
- 医生原型提供了患者概述和咨询的历史数据查询.
结论:
- 开发的系统支持远程患者自我监测和医生咨询.
- 在挪威卫生领域实施临床验证和监管批准是必要的.
- 该系统的设计有助于改善患者参与和医生监督.
更多相关视频
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
8.7K
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
441
相关概念视频
Pulse rhythm
814
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
814
Holter Monitor: 24-Hour Monitoring
23
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
23
Equipments Used To Measure Blood Pressure
986
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
986
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K
Special considerations while measuring blood pressure
729
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
729
Pulse Oximetry
340
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
340