基于PPG形态特征的脉冲到达时间和PPG形态特征的定量分析:糖尿病和非糖尿病组之间的比较研究
Seongryul Park1, Seungjae Lee2, Eunkyoung Park3
1Department of Electronic Engineering, Hanyang University, Seoul, 04763 South Korea.
Biomedical engineering letters
|October 24, 2023
概括
糖尿病疾病显著影响使用脉冲到达时间 (PAT) 和PPG特征的无袖血压估计. 不同的血管特性需要量身定制的模型来准确监测糖尿病患者的血压.
科学领域:
- 生物医学工程 生物医学工程
- 心血管研究研究心血管研究
- 医疗信息学 医疗信息学
背景情况:
- 使用脉冲到达时间 (PAT) 和光斑血压 (PPG) 形态特征的无袖血压 (BP) 估计正在引起人们的兴趣.
- 糖尿病等疾病对这些BP估计方法的影响尚不清楚.
研究的目的:
- 用PAT和PPG形态特征量化分析糖尿病对血压估计的影响.
- 为了比较糖尿病人和非糖尿病人的血压估计表现.
主要方法:
- 利用了来自VitalDB的112名糖尿病患者和308名非糖尿病患者的数据.
- 提取了16个特征,包括PAT,PPG形态特征和心率.
- 采用线性回归模型来比较BP估计性能和组之间的特征重要性.
主要成果:
- 基于PAT的血压估计在糖尿病组中显示出明显更高的误差 (标准偏差和平均绝对误差) (p < 0.01).
- 一组PAT和PPG形态特征的组合特征组在两组中产生了最佳的BP估计性能.
- 对于血压估计的特征的相对重要性在糖尿病和非糖尿病受试者之间有显著差异.
结论:
- 糖尿病疾病改变了血管特征,影响了无袖式血压估计的准确性.
- 对血压估计的最佳特征集根据个体血管特性而有所不同.
- 疾病特异型模型对于在不同患者群体中准确无袖血压监测至关重要.
相关概念视频
Sites for measruring blood pressure
1.8K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.8K
Assessment of blood pressure in brachial artery(two-step method)
726
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
726
Pre-Procedural Guidelines for Assessing Blood Pressure
574
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
574
Special considerations while measuring blood pressure
729
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
729
Assessing Blood pressure in the Leg
2.8K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
2.8K
Special considerations while measuring pulse
595
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
595