[通过吸烟器动脉穿孔测量动脉压的可行性研究]
1Department of Critical Care Medicine, Handan Hospital of Traditional Chinese Medicine, Handan 056000, Hebei, China.
Zhonghua wei zhong bing ji jiu yi xue
|October 24, 2023
概括
吸血器动脉导管治疗为手术期间的动脉压监测提供了一个可行的替代方案. 与传统的辐射动脉穿刺相比,这种方法显示出血瘤的发生率较低.
科学领域:
- 麻醉学和重症监护医学
- 血管接入技术 血管接入技术
- 血液动力学监测 血液动力学监测
背景情况:
- 常规选择性手术需要可靠的血液动力学监测,通常涉及动脉压测量.
- 传统的辐射动脉穿刺是一种标准的技术,但可能会导致并发症.
研究的目的:
- 评估在接受选择性手术的患者中使用吸烟器动脉 (辐射) 来测量动脉压力的可行性.
- 为了比较吸烟器动脉导管的疗效和并发症率与传统的辐射动脉穿刺.
主要方法:
- 一项前性随机对照试验招募了252名接受选择性手术的患者.
- 患者被随机分为两组:传统的辐射动脉穿刺和吸烟器动脉穿刺用于血液动力学监测.
- 观察到的关键结果包括导管内置时间,血压读数和并发症发生率.
主要成果:
- 两组之间在导管内置时间上没有发现显著差异.
- 吸烟器动脉组显示出血瘤形成的发生率明显较低 (2.5%与4.6%相比).
- 在吸烟器组中,缩和腹缩血压测量显著更高.
- 影响动脉导管成功的因素包括性别,年龄和体重指数.
结论:
- 通过吸烟器动脉进行导管治疗,为动脉压力测量提供了一个可行的,可能更安全的替代方案.
- 与传统的辐射动脉方法相比,这种技术可能会降低血瘤形成的风险.
相关概念视频
Sites for measruring blood pressure
1.8K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.8K
Assessment of blood pressure in brachial artery(two-step method)
726
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
726
Equipments Used To Measure Blood Pressure
986
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
986
Measurement of Blood Pressure
975
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
975
Assessment of blood pressure in brachial artery(one-step method)
611
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
611
Pulse
547
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
547