紫外光光谱学表征在脱离离子水中的布洛芬酸聚合物的紫外光光谱表征
Gregorio Marbán1, Amparo Fernández-Pérez1, Sonia Álvarez-García2
1Instituto de Ciencia y Tecnología del Carbono (INCAR-CSIC), c/Francisco Pintado Fe 26, 33011, Oviedo, Spain.
Heliyon
|October 27, 2023
概括
布洛芬酸在水中形成聚合物,而不是单体. 存在着二聚体,32个单位和128个单位的聚合物,其临界微粒度为7.8 ppm,影响溶解.
科学领域:
- 物理化学 物理化学
- 制药科学 制药科学
背景情况:
- 了解药物聚合对于配方至关重要.
- 布洛芬在水溶液中的行为需要详细的描述.
研究的目的:
- 为了研究ibuprofen酸在脱离离子水中的聚合平衡.
- 为了确定热力学参数和总体订单.
- 探索pH,导电性和布洛芬聚合之间的关系.
主要方法:
- 使用紫外线可见光谱法来监测聚合.
- 开发了一个计算算法来分析吸收率数据.
- 使用电导度测量来检测聚合物形成.
主要成果:
- 单质布洛芬酸不存在;观察到二元和较大的聚合物 (32,128个单位).
- 估计的临界菌度 (CMC) 为7.8 ppm.
- 聚合物形成与pH (pKa=4.62以下) 和电导率的增加有关.
结论:
- 布洛芬存在于水中的聚合物,而不是单体.
- 这项研究为ibuprofen聚合提供了热力学见解.
- 这些发现与ibuprofen溶解和配方优化有关.
相关概念视频
IR and UV–Vis Spectroscopy of Carboxylic Acids
4.2K
In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
4.2K
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
5.7K
Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the...
5.7K
Spectroscopy of Carboxylic Acid Derivatives
2.4K
Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and...
2.4K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
2.7K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for...
2.7K
UV–Vis Spectrum
1.1K
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
1.1K
UV–Vis Spectrometers
1.4K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.4K