结合线上和线下二维液体染色学和质谱的组合,以全面描述mAb电荷变体,并为快速过程开发提供精确的指令
Xiaoqing Jin1, Bingfang He1,2
1College of Biotechnology and Pharmaceutical Engineering, Nanjing Tech University, Nanjing 211816, China.
International journal of molecular sciences
|October 28, 2023
概括
这项研究引入了一种快速的2D-LC-MS方法,以精确识别单克隆抗体 (mAb) 电荷变异. 该平台通过为流程优化提供快速,可操作的见解来加速治疗开发.
科学领域:
- 生物制药学分析分析
- 蛋白质的表征 蛋白质的表征
- 分析化学是一种分析化学.
背景情况:
- 单克隆抗体 (mAbs) 是关键的治疗药物,但它们的充电变异构成质量属性挑战.
- 描述mAb电荷变体的传统方法是复杂的,耗时的,劳动密集的.
研究的目的:
- 开发一个全面和快速的平台来表征mAb充电变体.
- 使用先进的分析技术,为生物工艺开发提供精确的指令.
主要方法:
- 结合线上和线下二维液态染色学与质谱学 (2D-LC-MS) 的结合.
- 在完整的蛋白质和水平上进行分析,以确定特定的修改.
- 使用了少量样品 (0.6 mg mAb) 和短分析时间 (在6小时内).
主要成果:
- 成功识别了6个不同的充电变体峰值在mAb1.
- 离线的2D-LC-MS确定了除化,氧化和C端K损失.
- 在线2D-LC-MS检测到谷甲和糖化,揭示了由于预处理器件而在线分析中错过的修改.
结论:
- 开发的在线和离线2D-LC-MS平台提供了全面,精确和快速的mAb充电变体的表征.
- 这种方法可以实现精确的工艺开发,专注于特定的修改,如针对性细胞培养优化的谷氨酸化.
- 该平台通过在数小时内提供可操作数据来加速治疗开发.
相关概念视频
Mass Spectrometry: Complex Analysis
800
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
800
Peptide Identification Using Tandem Mass Spectrometry
6.5K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.5K
Mass Spectrometry: Overview
5.3K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electrospray ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave...
5.3K
High-Performance Liquid Chromatography: Types of Detectors
593
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
593
High-Resolution Mass Spectrometry (HRMS)
1.4K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.4K
Mass Analyzers: Common Types
620
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
620