随机持续时间的切换污染控制问题的可持续最佳控制
Yilun Wu1,2, Anna Tur2, Hongbo Wang1
1College of Electronic Science and Engineering, Jilin University, Jilin 130012, China.
Entropy (Basel, Switzerland)
|October 28, 2023
概括
这项研究模拟了一个随机持续时间的n个玩家污染控制游戏,以找到可持续的战略. 独特的适应性战略确保利增长,同时保护环境.
科学领域:
- 环境经济学环境经济学
- 游戏理论 游戏理论
- 数学建模的数学建模
背景情况:
- 污染控制需要适应性策略,因为游戏持续时间不确定和季节性波动.
- 之前的模型往往忽视了随机游戏终止和玩家异质设备的复杂性.
研究的目的:
- 为了研究一个可持续的和适应性的策略,为n玩家的污染控制差异游戏随机持续时间.
- 在合作游戏框架内定义环境可持续发展的条件.
主要方法:
- 建模一个n玩家交换的污染控制差异游戏,有两个随机持续时间的场景.
- 使用Pontryagin的最大原则来获得独特的控制解决方案.
- 分析状态变量的趋同到稳定的混合极限周期.
主要成果:
- 以混合极限循环的形式获得了一个独特的控制解决方案.
- 结果显示,状态变量趋于稳定的混合极限周期.
- 所有参与者的总回报显示了最初的增长,随后的趋同.
结论:
- 由此产生的环境可持续战略平衡了利增长与环境保护.
- 这种策略是独一无二的,适用于具有开关和随机持续时间的n玩家合作差分游戏.
- 该模型提供了在复杂的经济环境系统中实现可持续发展的见解.
相关概念视频
Time-Domain Interpretation of PD Control
123
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
123
Time and frequency -Domain Interpretation of PI Control
140
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
140
PD Controller: Design
250
In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
250
PID Controller
121
Proportional-Integral-Derivative (PID) controllers are widely used in various control systems to enhance stability and performance. In a thermostat, it adjusts heating or cooling based on the temperature difference between the actual and desired levels. They are often used in automotive speed systems, effectively managing sudden speed changes while maintaining a constant speed under varying conditions. On the other hand, PI controllers, commonly employed in voltage regulation, enhance stability...
121
Censoring Survival Data
108
Survival analysis is a statistical method used to analyze time-to-event data, often employed in fields such as medicine, engineering, and social sciences. One of the key challenges in survival analysis is dealing with incomplete data, a phenomenon known as "censoring." Censoring occurs when the event of interest (such as death, relapse, or system failure) has not occurred for some individuals by the end of the study period or is otherwise unobservable, and it might have many different...
108
Open and closed-loop control systems
768
Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
768